New Wall Construction

1. Select a suitable location that is not susceptible to 

moisture and is away from drapes, furniture and high 

traffic.

2. Place the fireplace in the desired location to see how 

it will look in the room.

3. Mark the desired location on the floor.

4. Use studs to frame an opening as per Fig. 3.

Option #1

The power cord can be run from behind the trim and 

along the wall to an outlet near the fireplace.

Option #2

A new outlet can be installed inside the framing 

construction. Plug the fireplace into a 10-13Amp/230-

240 Volt outlet. If the cord does not reach you may use 

a 3-core type extension cord rated for a minimum of 

10 Amps.

Existing Fireplace

1. Seal all drafts and vents with a non-fibrous insulation 

material to prevent any chimney debris from falling 

onto the fireplace. Do not install into an existing 

fireplace that is prone to dampness.

2. Cap the top of the chimney flue to prevent rain from

entering.

3. Plan your electric power supply.

4. The power cord can run along

the front of the hearth to an

outlet near the fireplace.

Installing Front Glass- 

See Fig. 5,6 & 7

NOTE: The outer glass is shipped seperate to the firebox.

1. Remove the three screws holding the side trim as shown 

in Fig. 5. and remove the metal trim.

2. Unpack the glass, ensure it is free from dust and finger 

marks and slide in to position as shown in Fig. 6.

3. Position the metal trim removed in step 1, and secure 

with the three screws as per Fig. 7

Remote Control - 

See Fig.2

The maximum range of use is ~ 5metres.

NOTE: It takes time for the receiver to respond to the 

transmitter.

NOTE: The reciever for the remote control is located in 

the display, aim the remote control in this direction when 

inputting commands.

Do not press the buttons more than once within two 

seconds for correct operation.

Battery Information - 

See Fig. 2

1. To activate the remote control remove the clear battery 

isolation strip at the base of the remote control, which 

is used to ensure your remote control reaches you fully 

charged.

2. To replace the remote control battery, turn over the 

remote control, and follow the diagram embossed on the 

remote control

3. Only use CR2025 or CR2032 size of batteries.

Fitting- 

See Fig. 3 & 4

IMPORTANT: If not using a Dimplex mantel, the fireplace 

must be installed in an enclosure with the following 

MINIMUM dimensions(Figure 3).

The firebox must be secured in place, using the L-Brackets 

supplied with this product, to fit these brackets please follow 

the steps shown in Fig. 4.

1. Select a suitable location that is not susceptible to 

moisture and is at least 1 meter away from drapes, 

furniture and high traffic.

2. Store the fireplace in a safe,

dry and dust free location.

3.  Clearance  for  air  circulation  beneath  the  fireplace 

is provided by two spacers. DO NOT INSTALL FIREPLACE 

DIRECTLY ON CARPET OR SIMILAR SURFACES WHICH MAY 

RESTRICT  AIR  CIRCULATION.  If  installing  the  fireplace  in 

a carpeted area, place a one-piece, solid flat surface 

under the fireplace. Ensure that all feet rest securely on 

this surface! 

4. In some jurisdictions this appliance is supplied without 

a plug this is to comply with the local regulations. In such 

instances this appliance must be installed by a suitabily 

quailified installer and the means for disconnection must 

be incorporated in the fixed wiring in accordance with 

the local wiring rules.

Summary of Contents for DF2624L-INT

Page 1: ...roduct complies with the European Safety Standards EN60335 2 30 and the European Standard Electromagnetic Compatibility EMC EN55014 EN60555 2 and EN60555 3 These cover the essential requirements of EE...

Page 2: ...A B C E F G 695mm 595mm 182mm 205mm 1 2 A C F B D E G...

Page 3: ...587mm 686mm 210mm 3 5 6 7 4...

Page 4: ...ildren aged from 3 years and less than 8 years shall not plug in regulate and clean the appliance or perform user maintaince The appliance must be positioned so that the plug is accessible Although th...

Page 5: ...is setting will be indicated by the LOW HEAT icon and the letters LO appearing in the display This icon is Orange in Colour High Heat This icon in the floating display indicates HIGH HEAT this setting...

Page 6: ...nsmitter NOTE The reciever for the remote control is located in the display aim the remote control in this direction when inputting commands Do not press the buttons more than once within two seconds...

Page 7: ...r general cleaning use a soft clean duster never use abrasive cleaners The glass viewing screen should be cleaned carefully with a soft cloth DO NOT use proprietary glass cleaners To remove any accumu...

Page 8: ...8 3 3 8 3 8 DF2624L INT 230V 240V P Nom 1 3 1 4 P 1 3 1 4 P c 1 3 1 4 In Standby mode el SB 0 39 0 41 W RU...

Page 9: ...5 8 0 0 5 SLEEPTIMER C FLAME EFFECT 4 LOWFLAME HIGHFLAME DEMOMODE OFF f1 F1 f2 F2 fp FP D LOG EFFECT 3 Lp FP LS FS E HEAT 4 LOW HEAT HIGH HEAT COOL BLOW OFF 1 5 LOW HEAT LO HIGH HEAT HIGH HEAT HI COO...

Page 10: ...1 2 3 4 3 1 2 10 13 230 240 3 10 1 2 3 4 5 6 7 1 5 2 6 3 1 7 2 5 2 1 2 3 CR2025 CR2032 3 4 Dimplex 3 L 4 1 2 3 4...

Page 11: ...LED...

Page 12: ...8 3 8 3 8 DF2624L INT 230 240 P Nom 1 3 1 4 P min 1 3 1 4 P max c 1 3 1 4 el SB 0 39 0 41 UK...

Page 13: ...3 A STANDBY 0 5 0 5 8 0 C FLAMEEFFECT 4 f1 F1 f2 F2 fp FP D LOG EFFECT 3 Lp FP LS FS E HEAT 4 1 5 LO HI CB 10 20 F 1 C 5 C 3 G 1 C 37 C 3 C F 2...

Page 14: ...1 2 3 4 3 1 2 10 13 230 240 10 1 2 3 4 5 6 7 1 3 5 2 6 3 1 7 2 5 2 1 2 3 CR2025 CR2032 3 4 Dimplex 3 L 4 1 1 2 3 4...

Page 15: ......

Page 16: ...huit ans ne doivent pas brancher r gler IMPORTANT THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE ou nettoyer l appareil ni effectuer aucune des op rations de nettoyage...

Page 17: ...l ic ne correspondante et les lettres LO l cran Cette ic ne est orange Chaleur lev e Cette ic ne sur le Floating Display indique une chaleur lev e HIGH HEAT Les lettres HI appara tront l cran Cette i...

Page 18: ...le r cepteur r ponde l metteur REMARQUE le r cepteur de la t l commande se trouve dans l cran Viser dans sa direction avec la t l commande lorsque l on souhaite commander l unit distance Do not press...

Page 19: ...ffon de d poussi rage propre Ne jamais utiliser de produits nettoyants abrasifs La vitre permettant de voir les flammes doit tre nettoy e d licatement avec un chiffon doux DO NOT use proprietary glass...