18
8. Insert new bulbs.
9. Install the left side of the flame rod to the mounting bracket.
10. Reconnect the Log Set LED Wire harness.
11. Replace the Log Set by
inserting the rear tab of the
Ember Bed under the mirror
and push down on the front
edge of the Ember Bed until it
snaps into place (Figure 9).
!
NOTE:
Ensure the Log Set is
installed tightly under the back
ledge to prevent light leakage.
12. close the Bi-fold doors.
Upper Light Bulb Requirements
Quantity of two (2) clear chandelier
or candelabra bulbs with an E-12
(small) socket base, 25 Watt rating.
Do not exceed 25 Watts per bulb.
To access the upper light bulb
area:
1. Open the Bi-fold doors.
2. Remove upper light bracket with
a screwdriver (Figure 10).
3. Replace bulb.
4. Reassemble in the reverse order
as above.
Purifire™ Filter
(Figure 11)
The Purifire™ filter supplied in your fireplace is reusable and washable.
The filter should be cleaned or replaced on average once a year.
To clean the filter gently tap filter on a hard surface to dislodge any
loose dirt or debris, and then clean with water. No soap or cleaning
products are recommended. The filter size is 20 inches x 10 inches
Side Section
Front
Edge
Log
Ember
Bed
Back
Ledge
Rear
Tab
Figure 9
Figure 10
Upper Light Bracket
Upper Light
Screw