10
6. Pull the front edge
of the plastic Ember
Bed or plastic grate
up and forward until
the rear tab releases
from the ledge
located at the bottom
of the Mirror
(Figure 6).
!
IMPORTANT:
Only
handle the Log Set
Assembly by the Ember Bed or plastic grate.
!
NOTE:
Log Set Assembly fits tightly into firebox, some
force may be necessary to remove.
7. Disconnect LED harness (Figure 7).
8. Set Log Set Assembly in front of firebox.
Mirror Replacement
If the fireplace was operating prior to servicing allow at least
five (5) minutes for light bulbs and heating element to cool off
to avoid accidental burning of skin.
Disconnect power before attempting any maintenance or
cleaning to reduce the risk of electric shock or damage to
persons.
Replacement Procedure
1. Slide firebox out of mantel.
2. Lay unit on it’s back for safe removal of Front Glass.
3. Remove four (4) Phillips screws from the right side of
Trim (Figure 4, page 7).
4. Remove Trim.
5. Slide glass to right side of fireplace to remove (Figure 4).
CAUTION:
Even though the glass is safety glass it may
break if bumped, struck of dropped. Care must be
taken when handling the glass.
6. Pull the front edge of the plastic Ember Bed or plastic
grate up and forward until the rear tab releases from
the ledge located at the bottom of the Mirror (Figure 6).
!
IMPORTANT:
Only handle the Log Set Assembly by the
Ember Bed or plastic grate.
!
NOTE:
Log Set Assembly fits tightly into firebox, some
force may be necessary to remove.
7. Loosen but do not remove the two (2) Philips screws that
clamp the Mirror in place, and swivel down so that the
clamp clears the edge of the Mirror (Figure 8).
Mirror
Clamp
Figure 8
Back
Ledge
Log
Ember Bed
Rear
Tab
Front
Edge
Side Section
Figure 6
8. Push the Mirror out from behind to clear the frame and
remove.
9. Insert replacement Mirror top end first and lay the bottom
end gently in the bottom track of the frame.
10. Tighten clamps back into place and re-assemble firebox
in reverse order as described above.
Figure 7
Log Set Assembly
LED Wire
Harness
Lower
Bulbs (3)
Plastic
Bushing
Flicker Rod
!
NOTE:
Lower bulbs are accessible without moving
Flicker Rod. If additional room is required, twist Plastic
Bushing as shown in inset of Figure 7 until it allows the
Flicker Rod to slide up from bracket. The spring on the
opposite end of the Flicker Rod is flexible enough to
allow Flicker Rod to be turned away, allowing greater
access to bulbs.
9. Unscrew bulbs counter clockwise to remove.
10. Insert new bulbs and screw in clockwise.
11. Move Flicker Rod back into place (if applicable) and
ensure Plastic Bushing is turned to lock rod in place.
14. Reconnect LED harness.
15. Install the Log Set Assembly by placing the front, bottom
edge of the Ember Bed in the track behind the control
panel. Once in place, push down on the back edge of
the Ember Bed until the rear tab snaps into place under
the Mirror (Figure 6).
16. Lay unit on it’s back and slide Front Glass back into
position and attach Trim.