17
Upper bulbs
Figure 9
Flicker rod
Glass media
and tray
Front Glass
Assembly
Maintenance
Upper Light Bulb Requirements
Quantity of two clear chandelier
or candelabra bulbs with an E-12
(small) socket base, 15 Watt rat-
ing.
Do not exceed 15 Watts per
bulb.
CAUTION:
Allow at least five
minutes for light bulbs to cool
before touching bulbs to avoid ac-
cidental burning of skin.
1. Carefully remove the front
glass assembly. Be aware
that some of the glass media
may fall out of the tray (Figure
9).
2. Upper bulbs are located in the
upper left and upper right cor-
ners of fireplace (Figure 9).
3. Remove the upper light cover
for each bulb (two (2) Philips
screws each).
4. Unscrew bulb(s) counter
clockwise.
5. Insert new bulb(s).
6. Re-install upper light bracket.
7. Replace glass assembly.
Figure 10
Exploded view to show detail
Flicker Rod
Flicker
Motor
Bulbs (3)
posite end of flicker rod back
into support bracket.
9. Replace media tray back into
firebox.
10. Gently pour and evenly
spread the glass media.
11. Replace glass assembly.