Maintenance

 WARNINg: 

Disconnect power before attempting 

any maintenance or cleaning to reduce the risk of 

fire, electric shock or damage to persons.

Light Bulb Replacement

Allow at least five (5) minutes for light bulbs to cool 

before touching bulbs to avoid accidental burning of 

skin. Light bulbs need to be replaced when you notice 

a dark section of the flame or when the clarity and 

detail of the log exterior disappears. There are two (2) 

bulbs under the log set which generate the flames and 

embers.

Helpful Hints

It is a good idea to replace all light bulbs at one time 

if they are close to the end of their rated life.  Group 

replacement will reduce the number of times you need 

to open the unit to replace light bulbs. 

Light Bulb Requirements

Quantity of three (3) – 60 Watt chandelier or 

candelabra bulbs with E-12 (small) socket base,  

120 Volt. 

Do not exceed 60 Watts per bulb.

Bulb Replacement Instructions:

  Unplug the unit from the outlet.

  Remove glass assembly as shown in Figure 4.

  Reach in and turn the burnt-out bulb(s) (or all 

bulbs) counter-clockwise to remove.

  Replace with new bulbs.

  Fit glass assembly back in place.

  Plug in the fireplace. 

 

glass Cleaning

The front glass is cleaned in the factory during the 

assembly operation.  During shipment, installation, 

handling, etc., the front glass may collect dust 

particles, these can be removed by dusting lightly with 

a clean dry cloth.
To remove fingerprints or other marks, the glass can 

be cleaned with a damp cloth.  The glass should be 

completely dried with a lint free cloth to prevent water 

spots.  To prevent scratching, do not use abrasive 

cleaners or spray liquids on the glass surface.

Fireplace Surface Cleaning

To remove fingerprints or other marks, the exterior 

finish can be cleaned with a damp cloth with a mild 

detergent.  The surface should be completely dried 

with a lint free cloth to prevent water spots.  

To prevent scratching, do not use abrasive cleaners or 

spray liquids on any surface.

Summary of Contents for DWF1146GP

Page 1: ...d this manual first before attempting to install or use this fireplace For your safety always comply with all warnings and safety instructions contained in this manual to prevent personal injury or pr...

Page 2: ...frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio or television reception which can be determined by turning the equipment off...

Page 3: ...electric fireplace can be found on the rating label located on the bottom of the unit see above Before installation please record your fireplace s serial number above for future reference The serial...

Page 4: ...y manner Do not use on soft surfaces like a bed where openings may become blocked All electrical heaters have hot and arcing or sparking parts inside Do not use in areas where gasoline paint or Import...

Page 5: ...ing bracket is designed for use with Dimplex wall mounted fireplaces only Improper use or use for purposes other than intended may cause damage or injury Installation WARNING Failure to install the Sa...

Page 6: ...crewdriver into the recess of the anchor Press the anchor into the wall in the desired marked position while turning the anchor clockwise until it is flush with the wall Insert the wall anchor screws...

Page 7: ...irebox Figure 8 Once complete use the enclosed rake to make sure the rock media is level in the firebox Figure 9 WARNING When raking the rocks be careful that the rake does not scratch the mirror Repl...

Page 8: ...heater overheat an automatic cut out will turn the heater off and it will not come back on without being reset It can be reset by switching the Main On Off Switch to Off and waiting five 5 minutes be...

Page 9: ...bulb Bulb Replacement Instructions Unplug the unit from the outlet Remove glass assembly as shown in Figure 4 Reach in and turn the burnt out bulb s or all bulbs counter clockwise to remove Replace wi...

Page 10: ...ct incorrect installation improper maintenance or handling or operation with an incorrect power source What you must do to get service under this limited warranty Defects must be brought to the attent...

Page 11: ...n Off On Switch 2800071100RP Remote Receiver 3000380200RP Flicker Rod 5901070200RP River Rocks 1400080200RP Control Knob 8800620100RP Cutout 2300270400RP Cordset 4100190100RP Terminal Block 4000070100...

Page 12: ...anel 3 Refer to instruction manual 4 Initialize the remote control 5 Install new battery into remote 6 If problem persists contact technical support Flame frozen or shutters Contact technical support...

Reviews: