With a pair of needle nose pliers, open the strain relief
7.
bushing that holds the power cord in place on the junc-
tion box cover and remove the cord.
Feed the new power cord through the junction box and
8.
squeeze the new strain relief in place on the cord and
junction box.
Re-connect wires. –(Wide blade on the plug is the neu-
9.
tral side of the power cord).
Re-assemble in the reverse order as above.