14
www.dimplex.com
HEATER ASSEMBLY
VIEW FROM BOTTOM OF ASSEMBLY
MANUAL CONTROLS
Heater/Blower Motor
Heating Element - Connects
to Heater/Blower Motor and
Terminal Block
Connects to Lower Heating
Element
Connects to Upper Heating
Element
Elements
Line In from Cutout and
Connection to Upper
Heating Element
High Temperature Cutout
- Line in From Thermostat,
Line out to Heater
Upper Heating Element -
Connects to Heater/Blower
Motor and From Terminal
Block
Heater On/Off
Switch
Main On/Off/Remote
Switch
Thermostat Control Assembly
Line In from
Power Cord
“L” on Remote
Receiver Board
Connects to
Cutout on Heat-
ing Assembly
Connects to “Switch Output” on
Remote Receiver Board and Po-
sition 1 on Main On/Off Switch
Connects to
Location 2 on
Heater On/Off
Switch
Connects to Thermostat
Control Assembly
Heater On/Off
Switch