background image

3

Remote Control

The fireplace is supplied with a radio frequency remote 

control.  This remote control has a range of approximately 

50 feet (15.25 m), it does not have to be pointed at the 

fireplace and can pass through most obstacles (including 

walls).  It is supplied with one of hundreds of independent 

frequencies to prevent interference with other units.

!

 NOTE: 

 Before attempting any operation with the 

remote, pull the plastic insulator strip out from between 

the remote casing and battery cover (Figure 2).

Remote Control Initialization/Reprogramming

If the hand held transmitter or receiver board has been 

replaced, follow these steps to initialize the transmitter and 

receiver:

Ensure that power is supplied through the main service 

1. 

panel.

Turn Main On/Off Switch to 

2. 

 (Figure 1A).

Within

3. 

 10 seconds press any button on the remote 

control transmitter. If the unit does not initialize, turn the 

main power switch off for 30 seconds and try starting at 

Step 1.

This will synchronize the remote control transmitter and 

receiver.

Remote Control Usage

The remote control operates the fireplace levels 

sequentially (from off):  flames only; to flames and low heat; 

to flames and high heat. 

The level is increased every time the ON button is pressed 

on the remote control transmitter and the fireplace can be 

turned off at any point by pressing the OFF button.

Battery Replacement 

To replace the battery:

Slide battery cover open on the hand held transmitter  

1. 

(Figure 2).

Install one (1) 12-Volt (A23) battery in the battery 

2. 

holder.

Close the battery cover

3. 

Battery must be recycled or disposed of properly. 

Check with your Local Authority or Retailer for 

recycling advice in your area.

OPERATION

Figure 1

The controls are located on the bottom surface of the 

Sahara fireplace on the right side (Figure 1).  

A. Main ON/OFF Switch

The switch has two ON positions marked with   and 

“Manual”.
The “Manual” position is for manual operation. In this 

position the built-in remote control is by-passed.
The   position is for operating the unit with the provided 

remote control.
When in   position the unit is operated with the ON and 

OFF buttons of the remote control.

When the switch is in the center position the unit is off.

B. Heater ON Switch

 

The Heater ON/OFF Switch supplies power to the heater 

fan and the heater element.  When the switch is in the ON 

position the heater operates if the thermostat calls for heat. 

C. Heater Thermostat Control 

To adjust the temperature to your individual requirements, 

turn the thermostat control clockwise all the way to turn 

on the heater.  When the room reaches the desired 

temperature, turn the thermostat knob counter clockwise 

until you hear a click.  Leave in this position to maintain the 

room temperature at this setting.  For additional heat, turn 

clockwise until you hear the click again and the heater will 

turn on. 

Resetting the Temperature Cutoff Switch

Should the heater overheat, an automatic cut out will turn 

the fireplace off and it will not come back on without being 

reset.  It can be reset by switching the Main On/Off Switch 

to Off and waiting five (5) minutes before switching the unit 

back on.

 CAUTION:  

If you need to continuously reset the heater, 

disconnect power and call Dimplex customer service at 

1-888-DIMPLEX (1-888-346-7539).

Figure 2

Off Button

On 

Button

Battery 

Cover

Plastic 

Strip

Front View

Bottom View

Control Location

A

B

C

Summary of Contents for EWF-SS

Page 1: ...orth America Limited Dimplex North America Limited 1367 Industrial Road Cambridge ON Canada N1R 7G8 1 888 346 7539 www dimplex com REV PCN DATE 00 2 SEP 11 IMPORTANT SAFETY INFORMATION Always read thi...

Page 2: ...s and techniques which if not carefully followed will expose the user to the risk of fire serious injury or death OPERATION 3 Maintenance 4 Exploded Parts Diagram 5 Wiring Diagram 6 PREPARATION FOR SE...

Page 3: ...sed of properly Check with your Local Authority or Retailer for recycling advice in your area OPERATION Figure 1 The controls are located on the bottom surface of the Sahara fireplace on the right sid...

Page 4: ...placement Instructions Unplug the unit from the outlet 1 Remove glass assembly as shown in Figure 3 2 Reach in and turn the burnt out bulb s or all bulbs 3 counter clockwise to remove Replace with new...

Page 5: ...0RP Flicker Assembly 4 5901070200RP Cutout 5 2300270400RP Cord Set 6 4100190100RP Lampholder Wire Assembly 7 2500450100RP Remote Receiver 8 3000380200RP 3 Position Switch 9 2800071100RP 2 Position Swi...

Page 6: ...6 www dimplex com Wiring Diagram...

Page 7: ...ock or damage to persons Remove the screws which secure the heater assembly 1 to the back panel 4 Smaller screws secure the mount ing bracket in the lower center of the back panel 2 on left bracket an...

Page 8: ...the housing below the flicker motor Turn the unit over and lay it on to its front to secure 23 the remaining 6 screws from behind the back panel 4 for the fan housing panel and 2 for the switch housi...

Page 9: ...s slightly bend the flanges that 15 are holding the wire harness in the channel Bend them just enough to feed the wires out of the channel Remove the 2 screws that are securing the wire har 16 ness to...

Page 10: ...the switches and bottom closest to you Locate the switch housing cover on the lower interior 2 right side Remove the 2 screws which secure the upper housing cover just below the flame motor to the el...

Page 11: ...lace on the junc tion box cover and remove the cord Feed the new power cord through the junction box and 8 squeeze the new strain relief in place on the cord and junction box Re connect wires Wide bla...

Page 12: ...PART PICTURES Light Socket Bracket and Bulbs Light Harness Channel Heat Deflector Grille Flicker Rod and Bracket Thermostat Dial and Control Rear Flame Panel Flicker Rod Heater Assembly and Cover Ligh...

Page 13: ...ote Receiver Board Heater On Off Switch Black wire from Flicker Motor and Neutral from Remote Receiver Board Switch Output Heater On Off Switch and Terminal Block Capacitor and Brown wire from Flicker...

Page 14: ...gh Temperature Cutout Line in From Thermostat Line out to Heater Upper Heating Element Connects to Heater Blower Motor and From Terminal Block Heater On Off Switch Main On Off Remote Switch Thermostat...

Page 15: ...et Check Fuse Breaker Panel Defective Main On Off Remote switch Replace Main On Off Remote switch Defective circuit board Replace circuit board Loose wiring Check wiring connections Fireplace does not...

Page 16: ...ce thermostat Loose wiring Trace wiring in unit Defective heater assembly Replace heater assembly Heating element is glowing red Normal Operation Small glowing sections of the element are considered n...