background image

 

 

Operating and Installation Instructions

 

 

FX 20 V   Downflow Fan Heater 

453321.66.70gb   09/03/A

 

 
1. Warnings 

You are requested to read carefully all the information in 
these instructions. Keep these instructions carefully and if 
applicable pass them on to the final owner. 

− 

The appliance is only to be used for the heating of 
dwellings or similar spaces. It is only suitable for domestic 
use or similar purposes within enclosed spaces. 

− 

Repairs to the appliance are only to be carried out by a 
competent electrician.  

− 

In the event of a fault disconnect the electricity supply to 
the appliance (turn off or remove the fuse).  

− 

By covering the heater could cause a heat build up and 
possibly lead to material igniting. You must observe the 
minimum clearances. 

− 

The surfaces, especially the air-outlet grille, become hot 
during operation. For this reason ensure that small 
children cannot touch these surfaces. 

− 

No objects should be inserted through the openings of 
the appliance. 

− 

It is particularly important that the appropriate safety  

− 

regulations for bathrooms, showers, swimming pools 
etc. are fulfilled. 

− 

The heater is to be installed in such a way that it cannot 
be touched from a person in the bath or shower and that 
the switch cannot be operated. 

− 

The fixed installation must be provided with a switching 
device having a contact separation of 3 mm in all poles 
(e.g. overload release). 

− 

No materials can be used in the room where the 
appliance is installed whose fumes or the material itself 
could give rise to ignition, explosion or thermal 
decomposition due to the high temperatures. 

2. Description  

Heating capacity : 2 kW, 1 kW (depending on pre-setting) 
Supply voltage : 1/N/~230V, 50 Hz 
Construction class II: double insulated 
System of protection: IP 22 
Dimensions (W x H x D) : 229 x 109 x 242

 

mm 

Weight : 1.4 kg 

3. Minimum clearances, installation  

The sketch below shows the drilling dimensions and the 
dimensions for the cable entry. 
 

229

188

116

100

12

242

30

 

 
 

• 

The minimum clearances given in the mounting sketch 

are to be observed.  

• 

The heater must not be located immediately below a 

fixed socket outlet. 

• 

Do not place easily combustible objects, such as 

curtains or heat sensitive plastics, in the direct airflow 

from the unit. 

• 

The fan heater should only be mounted on a vertical 

wall as shown in the sketch below. 

• 

Furthermore there must be a clearance of at least 350 

mm from the front of the heater. 

To fix the heater, remove the two screws securing the top 

cover and remove the cover from the heater. 

− 

Mark the position of the keyhole slots on the wall, drill 

and plug for the two suitable screws (see sketch for 

position).  

− 

Partially insert the two screws, then hang the appliance 

on these screws and mark the position of the lower 

positioned screw.  

− 

Remove the appliance, drill and plug the third screw.  

− 

Remount the appliance on the wall and insert the supply 

cable. Ensure that the appliance is horizontal and fix in 

position by tightening the three screws. 

1800

300

250

600

242

229

 

4. Electrical connection 

 

Take care! The appliance must be installed by a 

competent electrician. 
The appliance may be connected directly to a fixed wiring or 
to a flexible supply cable H05VV-F 2 x 1.0 mm² from a wall 
connecting box. 
The heater must not be located immediately above the wall 

connecting box. 

GB 

Reviews: