background image

FXL(i)

 

FAN STORAGE HEATER RANGE

 

MODELS:  FXL12i - 1.7kW / 12kWh STORAGE & 1.5kW BOOST

 

 

 

FXL18i - 2.6kW / 18kWh STORAGE & 1.5kW BOOST

 

 

 

FXL24i - 3.4kW / 24kWh STORAGE & 1.5kW BOOST

INSTALLATION 

 

AND 

 

OPERATING

INSTRUCTIONS

IMPORTANT

PLEASE READ THIS LEAFLET CAREFULLY AND  RETAIN FOR FURTHER USE.  

NOTE ALSO THE INFORMATION GIVEN ON THE HEATER

 

The Installation must be carried out by trained personnel.

 

A means for disconnection must be incorporated in the 

fi

 xed wiring by a double pole switch 

with a contact separation of a minimum of 3mm and in accordance with the current IEE Wiring 

Regulations.

 

The heater must not be installed immediately below a 

fi

 xed socket outlet.

 

The heater is not suitable for connection to a 30A ring circuit.

 

Do not position the heater under windows where curtains can contact the heater casing.

 

WARNING - THE SURFACES ON THIS HEATER CAN BE HOT.

 

This heater meets EN60335 safety requirements.  However, any heater type becomes hot in normal 

operation.  Care must be taken to ensure that prolonged skin contact with the heater does not occur.

 

WHERE YOUNG CHILDREN, INFIRM PERSONS, OR THE AGED ARE PRESENT THIS APPLIANCE 

MUST BE ADEQUATELY GUARDED. Contact your installer or the manufacturer for further advice.

 

This appliance is not intended for use by persons (including children) with reduced physical, sensory or 

mental capabilities, or lack of experience and knowledge, unless they have been given supervision for 

instruction concerning use of the appliance by a person responsible for their safety.  Children should 

be supervised to ensure that they do not play with the appliance.

 

This appliance is very heavy and must be securely fixed to a wall.  DO NOT UNDER ANY 

CIRCUMSTANCES ATTEMPT TO MOVE OR REPOSITION THIS HEATER WITHOUT SEEKING 

EXPERT ADVICE.

 

To maintain stability, it is essential that the heater is placed on a level surface.

 

This heater must be installed where it is impossible for switches and other controls to be touched by 

a person using a bath or shower.

 

IMPORTANT - Due to the newness of materials the heater will produce a slight smell for the 

fi

 rst few 

days of operation.  ROOMS MUST BE WELL VENTILATED AND YOUNG CHILDREN, CAGED BIRDS, 

OR PERSONS WITH RESPIRATORY COMPLAINTS MUST NOT REMAIN IN CLOSE PROXIMITY 

TO THE HEATER DURING THE FIRST 48 HOURS OF THE COMMISSIONING PERIOD.

 

IF, DURING ANY REASSEMBLY OF THE HEATER, A PART OF THE THERMAL INSULATION SHOWS 

DAMAGE OR DETERIORATION WHICH MAY IMPAIR SAFETY, IT SHOULD BE REPLACED BY AN 

IDENTICAL PART.

88472

Summary of Contents for FXL12i

Page 1: ...Y GUARDED Contact your installer or the manufacturer for further advice This appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision for instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure t...

Page 2: ...e top edge whilst pressing down on the top panel with your thumbs The panel can now be lifted clear and set to one side Remove the packing pieces from the slots on the inner front 2 on the FXL12i 3 on the FXL18i and 4 on the FXL24i 2 Remove the inner front panel by unscrewing the screws along its top and sides As the front insulation is attached care must be taken when lifting this panel from the ...

Page 3: ...ent to allow access for the back rows of bricks On the FXL24i remove the element to the right of centre on the FXL18i remove the central element and on the FXL12i the left hand element should be removed Loosen the two screws securing the element tails in the ceramic connector block and lift the element up and out of the heater 11 Carefully fit the bottom row of the back layer of bricks placing the...

Page 4: ...oost being activated until the core is partially depleted When the core is almost fully depleted the direct acting element will automatically switch to full power full boost Dependent on the option the installer has chosen see installation instructions point 4 the fan and boost will operate as follows Option 1 two stage fan recommended for domestic installations If boost option is not selected Nor...

Reviews: