After Sales Service

Please see the separate Warranty leaflet for details of your Warrantee
& after sales service including contact details.
Should you require after sales service, please get in touch with the
supplier through whom you purchased the appliance, or the contact
number on your Warranty leaflet.

Using the Thermostat

Plug in and set all switches to ON. Turn the thermostat knob to MAX
to warm the room rapidly. When the room temperature has reached
the desired level, turn the thermostat knob back slowly until the
thermostat just clicks off. The heater will then maintain the room
temperature at the chosen level - see Fig. 2.

NOTE

 – Should your heater fail to come on when the thermostat is at

a low setting, this may be due to the room temperature being higher
than the thermostat setting

.

Using the Flame control

This unique effect may be enjoyed whether or not the heating elements
are in operation.

Brightness and flame effect control gives a choice of light and flame
setting. At minimum setting, the flame effect and the fuel brightness
will be lowest, indicated by a small bulb symbol on the control panel.
Clockwise rotation of knob  will increase the intensity of the effect
(indicated by bulb symbols increasing in size) – see Fig 2.

The heater controls are located behind the flap on the front of the
heater. (see Fig 1)
Three switches provide a choice of heat settings. A switch is in the
ON position when the side with the markings on (i.e. 

I

 , 

I

 , or 

II

 ) is

pushed in - see Fig. 2.

Controls

Maintenance

WARNING – BEFORE UNDERTAKING ANY MAINTENANCE OR
CLEANING REMOVE PLUG OR DISCONNECT FROM THE
ELECTRICITY SUPPLY.

To gain access to the lamps,
the four screws which se-
cure the back panel, must
be removed. Remove and
slide out panel as indicated
on Fig. 4

Two lamps are located behind the back panel as indicated in Fig.3.

Fig. 3

Fig. 4

Remove the defective lamp by unscrewing it as shown - see Fig. 5.
Replace with a 60W E14 SES Clear Candle lamp.
Take care not to over-tighten the lamp. Refit the back panel and
secure with the four screws.

Fig. 5

Safety cut-out

An automatic cut-out will switch off the heater if for any reason it
overheats. This could occur for instance, if the air inlet or outlet were
restricted in any way. If the cut-out operates, the heater will switch off.
The heater will switch on once the obstruction has been removed and
the heater has cooled. If the cut-out continues to operate intermittently,
the heater should be switched off and Customer Services contacted

Cleaning

For general cleaning use a soft clean duster – never use abrasive
cleaners. The viewing screen should be cleaned carefully with a soft
cloth. DO NOT use proprietary glass cleaners.

Lamp Replacement

II

I

I

O

ma

x

min

Flame control

knob

Thermostat control

knob

Switches 

3

2

1

Fig. 2

Switch 1 ( I )

Switch 2 ( 

I

 )

Switch 3 ( 

II

 )

Controls the electricity supply to the heater
and flame effect.
Note: This switch must be in the ON ( I )
position for heater to operate with or without
heat.

Provides 1kW heat output - thermostatically
controlled.

Provides 2kW output with switch 2 -
thermostatically controlled.

 

The product complies with the Australian/New Zealand Safety Standards AS/NZ S 335.2.30:1997 and 2002 Part 1 also the European Standard ElectromagneticCompatibility
(EMC)  EN 55 014-1:1993, EN 61000-3-2:1995, EN 61000-3-3:1995, EN 55 014-2:1997 which cover the essential requirements of EEC Directive 89/336/EEC.

Specification subject to change without prior notice.