15
Maintenance
WARNINg:
Disconnect
power before attempting any
maintenance or cleaning to
reduce the risk of fire, electric
shock or damage to persons.
Light Bulb Replacement
CAUTION:
Allow at least five
(5) minutes for light bulbs to cool
off before touching bulbs to avoid
accidental burning of skin.
Light bulbs need to be replaced
when you notice a dark section
of the flame or when the clarity
and detail of the log ember bed
exterior disappears. There are
three (3) bulbs under the log set
assembly which generate the
flames and embers, and two (2)
bulbs above that illuminate the log
exterior.
Helpful Hints
It is a good idea to replace all
light bulbs at one time if they are
close to the end of their rated life.
Group replacement will reduce
the number of times you need
to open the unit to replace light
bulbs. Care must be taken when
removing the log set as the log
set contains LED’s and wires.
Lower Light Bulb Requirements
Quantity of three (3) clear chan
-
delier or candelabra bulbs with an
E-12 (small) socket base, 60 Watt
rating. Example: GE 60BC or
Philips 60CTC.
Trim
Front Glass
Log Set Assembly
Figure 6
upper Light Bracket
Lower Bulbs
LED Wire Harness
upper Bulbs