Thermostat

Fig. 6

Thermal Safety Cut-out

A thermal safety cut-out is incorporated in the heater to pre-
vent damage due to overheating.
This can happen if the heat outlet was restricted in any way.
The heater will switch on once the obstruction has been re-
moved and the heater has cooled.  If the cut-out continues to
operate intermittently, the heater should be switched off and
a service agent contacted.

Maintenance

WARNING: ALWAYS DISCONNECT FROM THE POWER
SUPPLY

 

BEFORE ATTEMPTING ANY MAINTENANCE.

Instructions for fitting Coal Option

Introduction

Your fire is provided with a coal effect option. Simply follow
the instructions given below.

Removal of Log Effect

Remove the four screws securing the log effect

 

assembly and

slide out ( see Fig. 7).

Fitting Coal Effect

Fit the coal effect in position and secure with the four screws
(see fig. 8)
Place the coal lumps on the fuel bed. A plastic glove is pro-
vided for

 

handling the coal.

Note:

The log effect should be stored away for possible fu-

ture use.

Fig. 7

Fig. 8

Lamp Replacement

To gain access to the lamps remove the coal/log effect  from
the fire by unscrewing the four fixing screws from the fuel bed
and sliding out the fuel effect.
Unscrew any defective lamps (see Fig. 9) and replace
with240V, 25 watt E14 SES clear candle lamp. Do not
overtighten.
Refit fuel effect, securing with the four fixing screws.

Fig. 9

Summary of Contents for Rectory REC20R

Page 1: ...on long hair type of rugs The appliance must be positioned so that the plug is accessible If the supply cord is damaged it must be replaced by the manufacturer or service agent or a similarly qualified person in order to avoid a hazard Keep the supply cord away from the front of the heater Introduction These fires incorporate a flame effect which can be used with or without heating so that the com...

Page 2: ... ON button once Indication Bottom Neon Flame effect 1kW heat Press the ON button again Bottom Middle Neon Flame effect 2kW heat Press the ON button again All 3 Neon s To turn off any of the settings Press the OFF button once To increase or decrease the brightness of the fuel effect use the buttons as shown in Fig 5 Thermostat Operation see Fig 6 The thermostat controls the heat output according to...

Page 3: ...a coal effect option Simply follow the instructions given below Removal of Log Effect Remove the four screws securing the log effect assembly and slide out see Fig 7 Fitting Coal Effect Fit the coal effect in position and secure with the four screws see fig 8 Place the coal lumps on the fuel bed A plastic glove is pro vided for handling the coal Note The log effect should be stored away for possib...

Page 4: ...be given an occasional wipe over with a soft damp cloth Do not use detergents abra sive cleaning powder or polish on the body of the heater The viewing screens should be cleaned carefully with a cham ois leather DO NOT use proprietory glass cleaners To remove any accumulation of dust or fluff the soft brush attachment of a vacuum cleaner should occasionally be used to clean the outlet grille of th...

Reviews: