Operating Temperature
-20°-40°C
Fixed Wiring
In some jurisdictions this appliance is supplied without a plug. This is to comply with
local regulations. In such instances, this appliance must be installed by a suitably
qualified installer and the means for disconnection must be incorporated in the fixed
wiring in accordance to the local wiring rules.
WARNING:
Electrical outlet wiring must comply with local building codes and other
applicable regulations to reduce the risk of fire, electric shock or injury.
Note:
A 10Amp circuit is required. A dedicated circuit is preferred, but not essential
in all cases. A dedicated circuit will be required if, after installation, the circuit breaker
trips or the fuse blows on a regular basis when the heater is operating. Additional
appliances on the same circuit may exceed the current rating of the circuit breaker.
Unpacking the Unit
The unit comes packed with a protective sheet covering the front of the unit. This sheet
is intended to prevent dust and debris from entering during construction. This sheet
is designed so that it can be partially removed to complete the wiring and unpacking
and can be reinstalled until the final installation is complete.
The log set was installed on the grate and the grate permanently fixed to the firebox
at the factory.
Carefully remove the packaging from around the log set. Make sure the wires from
the log set are connected securely to the grate box.
CAUTION:
The Realogs contain LEDs to create a unique pulse and glow effect. Handle
the log set carefully. They are fragile and can crack or break if dropped.
Thermal Safety Cut-out
A thermal safety cut-out is incorporated in the fan heater to prevent damage due
to overheating. This can happen if the heat outlet was restricted in any way. If the
cut-out operates, unplug the heater from the socket outlet and allow approximately
10 minutes before reconnecting. Before switching the heater back on remove any
obstruction that may be restricting the heat outlet, then continue normal operation.
WARNING:
In order to avoid a hazard due to inadvertent resetting of the thermal cut-
out, this appliance must not be supplied through an external switching device, such
as a timer, or connected to a circuit that is regularly switched on and off by the utility.
Setup