Placement
This firebox is a zero clearance design, with the exception of the top of the unit, where
any insulation and vapour barrier should be placed a minimum of 2" (5.1cm) from the
firebox.
DANGER:
High temperatures may be generated under certain abnormal conditions.
Do not partially or fully cover or obstruct the front of the firebox.
WARNING:
All electrical heaters have hot and arcing or sparking parts inside. Do not
use it in areas where gasoline, paint or flammable liquids are used or stored.
WARNING:
The Bulit-in Electric Firebox must NOT be in direct contact with any
building vapour barrier or insulation.
1. Place the firebox into the framed opening. Level with shims if necessary.
2. From the inside of the unit, gently remove the interior brick panels (attached
magnetically) and bend out, up to 90°, to be flushed with the surrounding studs.
3. Attach the firebox to frame using four mounting flanges on the sides of the firebox
and suitable hardware.
Fixed Wiring
In some jurisdictions this appliance is supplied without a plug. This is to comply with
the local regulations. In such instances, this appliance must be installed by a suitably
qualified installer and the means for disconnection must be incorporated in the fixed
wiring in accordance with the local wiring rules.
Installation
9