background image

Important Safety Advice:

When using electrical appliances, basic precautions
should be followed to reduce the risk of fire, electric
shock, and injury to persons, including the following:

If the appliance is damaged, check immediately with the
supplier before installation and operation.

Do not use this heater in the immediate surroundings
of a bath, shower or swimming pool

.

Do not use outdoors.

This heater must not be located immediately above or
below a fixed socket outlet or connection box.

Do not cover or obstruct in any way the heat outlet grille
located underneath the heater. Overheating will result if
the heater is accidentally covered.

In the event of a fault unplug the heater.

Unplug the heater when not required for long periods.

The supply cord must be placed on the right hand side
of the heater away from the heat outlet underneath the
heater.

Although this heater complies with safety standards, we
do not recommend its use on deep pile carpets or on
long hair type of rugs.

This appliance is not intended for use by children or
other persons without assistance or supervision if their
physical, sensory or mental capabilities prevent them
from using it safely. Children should be supervised to
ensure that they do not play with the appliance.

The appliance must be positioned so that the plug is
accessible.

If the supply cord is damaged it must be replaced by the
manufacturer or service agent or similarly qualified
person in order to avoid a hazard.

Electrical

WARNING – THIS APPLIANCE MUST BE EARTHED

This heater must be used on an AC ~ supply only and the voltage
marked on the heater must correspond to the supply voltage.
Do not switch the appliance on until properly installed.  Please
read all the safety warnings and operating instructions.

General

Unpack the heater carefully and retain the packaging for
possible future use, in the event of moving or returning the fire
to your supplier.

Contents of Carton.

Heater.

Wall fixing bracket.

Fixing screws and wall plugs.

Remote control and batteries ( 3 AAA’s type).

Spare bulb.

Do not connect the heater to an electricity supply until it is
installed on a wall correctly. - see ‘Installation’.
A choice of 1kW or 2kW heat output is provided by the fan
heater, which is concealed underneath the unit.
The heater can be used remotely or manually. - see ‘Operation’.

Dimplex Wall Fires
Model(s): SP120, SP220, SP320 & SP820

IMPORTANT: THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE

General features of remote control are:

Heat output can be increased or decreased according
to your particular requirements.

The illumination of fuel effect can be increased or
decreased.

Please note: Used in an environment where background noise
is very low, it may be possible to hear the fan which operates
the flame effect. This is normal and should not be a cause for
concern.

Installation

Do not connect appliance until properly fixed to the wall
and the Instruction leaflet is read fully.
The minimum distances must be observed.

For installation of the appliance, care must be taken not to
damage concealed cables.
Please be careful while drilling the holes.
This model is designed to be permanently fixed to a wall at a
minimum height of 300mm.
The wall bracket must be fitted horizontally and the cable routed
to the bottom right of the heater as in 

Fig 1

.

A height of 600mm from bottom of heater to floor is recommended
for optimum viewing of fuel bed (see 

Fig. 2

 for recommended

fixing dimensions).
For optimum viewing mark the top two screw fixing positions on
wall in accordance with the recommended fixing dimensions -
see 

Fig. 2

.

Fix the wall bracket using the two plugs and screws provided -
see 

Fig 3

.

Carefully lift the heater up ensuring that the top rear ledge of
heater engages the wall bracket and is sitting centrally
positioned. - see 

Fig 4 

(b).

Rotate the bottom fixing bracket down. - see 

Fig 4

 (c).

Gently bring the heater level with the wall. - see Fig 4 (d).
Mark the bottom hole position (see 

Fig. 5

), remove the heater

ensuring that the bottom fixing bracket is rotated up.
Drill and fit wall plug.
Refit the heater to the wall fixing bracket (i.e. follow steps as in

Fig. 4

 a, b, c and d above) and rotate the bottom fixing bracket

down again and use the screw provided to permanently fix the
heater in place.
The heater should not be connected until the instruction leaflet
is read fully.

Manual Operation

The switches are located at the right side of the heater.
The Standby Switch (Switch S1) must be first turned ‘ON’ and
the AUTO/MAN (Switch S2) switch set to ‘MANUAL’ to operate
the manual controls - see 

Fig 6

.

Note : When the fire is put in Manual mode the first time the
flame effect will come on indicated by the Bottom neon coming
on for 3 seconds - see 

Fig 7

.

Remote Operation

The standby switch (S1) must first be turned ‘ON’ and the ‘AUTO/
MAN’ Switch turned to ‘AUTO’.
Note: It takes some time for the receiver to respond to the
transmitter. DO NOT PRESS the buttons more than once within
two seconds for correct operation.

Installation and Operating Instructions

UK

Reviews: