SYMPHONY ELECTRIC FIREPLACE 

 

 

 

 

 
If unit was operating prior to servicing allow at least 10 minutes for light bulbs and 
heating element to cool off to avoid accidental burning of skin. 
 
Disconnect power before attempting any maintenance or cleaning to reduce the 
risk of electric shock or damage to persons. 
 
Light bulbs need to be replaced when you notice a dark section of the flame or 
when the clarity and detail of the log exterior disappears.  There are two bulbs at 
the top of the opening that illuminates the log set exterior and four bulbs under 
the log set which generate the flames and embers. 
 
It is a good idea to replace all of the light bulbs at one time if they are close to the 
end of their rated life.  Group replacement will reduce the number of times you 
need to open the unit to replace the light bulbs. 
 
TO REPLACE LOWER LIGHT BULBS 
 

1.  Remove the firebox trim by placing your hand on the grill section, grasping 

the trim and pulling outwards releasing the retainer clips. 

 

2.  Remove the mounting screw in the center of the glass and remove the 

retainer bracket. 

 

3.  Remove the glass by lifting up from the bottom. 

 

CAUTION: Even though the glass is safety glass it may break if bumped, 
struck of dropped.  Care must be taken when handling the glass. 

 

4.  Only handle the log set by the ember bed and not by the logs. To remove 

the log set lift up the front edge of log set until it clears the front tabs.  Pull 
out until the rear tab clears the back ledge, and then lift out.  

 

5.  Replace bulb(s) that require replacement, holding onto the light socket 

when while unscrewing. 

  

6.  Replace the log by pushing it down and in until it rests against the mirror. 

 

7.  Reassemble in the reverse order as above. 

 
 

LOWER BULB-Quantity 4 chandelier or candelabra bulbs with an E-12 
(small) socket base, 60 watt rating. 
GE 60BC or Philips 60CTC 

 

CAUTION DO NOT EXCEED 60 WATTS PER BULB 

 
 

Summary of Contents for SYMPHONY SF5598

Page 1: ...SYMPHONY MODEL SF5598 PARTS SERVICE MANUAL...

Page 2: ...ER LIGHT BULB REPLACEMENT PAGE 8 MAIN POWER ON OFF SWITCH REPLACEMENT PAGE 9 LIGHT DIMMER SWITCH REPLACEMENT PAGE 10 FLAME SPEED CONTROL REPLACEMENT PAGE 11 FLAME MOTOR FLAME ROD REPLACEMENT PAGE 12 H...

Page 3: ...the thermostat control clockwise all the way to turn in the heater When the room reaches the desired temperature turn the thermostat knob counter clockwise until you hear a click Leave in this positi...

Page 4: ...ontrol 5 The remote control works up to 50 feet away 6 Push the ON button to turn stove on push the OFF button to turn the stove off NOTE To prevent the risk of fire the stove plug must be inserted fu...

Page 5: ...5 SYMPHONY ELECTRIC FIREPLACE...

Page 6: ...00200 8800000200 8800000200 8 HEATER ON OFF SWITCH 2800070200 2800070200 2800070200 9 THERMOSTAT KNOB 8800000300 8800000300 8800000300 10 THERMOSTAT 2300150100 2300150100 2300150100 11 FLAME PROJECTIO...

Page 7: ...heir rated life Group replacement will reduce the number of times you need to open the unit to replace the light bulbs TO REPLACE UPPER LIGHT BULBS 1 Remove the firebox trim by placing your hand on th...

Page 8: ...E LOWER LIGHT BULBS 1 Remove the firebox trim by placing your hand on the grill section grasping the trim and pulling outwards releasing the retainer clips 2 Remove the mounting screw in the center of...

Page 9: ...outwards releasing the retainer clips 2 Remove the firebox from the mantel 3 Lower the grill covering the controls 4 Remove the retaining screws on the top cover and remove the top placing it upside...

Page 10: ...utwards releasing the retainer clips 2 Remove the firebox from the mantel 3 Lower the grill covering the controls 4 Remove the retaining screws on the top cover and remove the top placing it upside do...

Page 11: ...he retaining screws on the top cover and remove the top placing it upside down on the top of the unit being careful not to damage any of the wiring 5 Locate the flame speed control mounted on the top...

Page 12: ...y and remove the wiring clips and connections noting their original locations 6 Remove the flame assembly mounting bracket screws and rotate the assembly forwards releasing the mounting tabs from the...

Page 13: ...ME ROD NOTE Removal of the glass eases the installation of the bottom cover 11 Remove the mounting screw in the center of the glass and remove the retainer bracket 12 Remove the glass by lifting up fr...

Page 14: ...outwards releasing the retainer clips 2 Remove the firebox from the mantel 3 Lower the grill covering the controls 4 Remove the retaining screws on the top cover and remove the top placing it upside...

Page 15: ...ner clips 2 Remove the firebox from the mantel 3 Lower the grill covering the controls 4 Remove the retaining screws on the top cover and remove the top placing it upside down on the top of the unit b...

Page 16: ...ox from the mantel 3 Lower the grill covering the controls 4 Remove the retaining screws on the top cover and remove the top placing it upside down on the top of the unit being careful not to damage a...

Page 17: ...the controls 4 Remove the retaining screws on the top cover and remove the top placing it upside down on the top of the unit being careful not to damage any of the wiring 5 Locate and disconnect the p...

Reviews: