background image

6  

www.dimplex.com

  

IMPORTANT INSTRUCTIONS

 WARNING: 

Remote control 

contains small batteries.  Keep away 

from children. 

If swallowed, seek 

medical attention immediately.

 WARNING: 

Do not install battery 

backwards, charge, put in fire or mix 

with used or other battery types - may 

explode or leak causing injury.

!

NOTE: 

Changes or modifications 

not expressly approved by the party 

responsible for compliance could 

void user's authority to operate the 

equipment. 

 CAUTION: 

This equipment has 

been tested and found to comply with 

the limits for Class B digital device, 

pursuant to part 15 of the FCC 

Rules. These limits are designed to 

provide reasonable protection against 

harmful interference in a residential 

installation. This equipment 

generates, uses and can radiate 

radio frequency energy and, if not 

installed and used in accordance with 

the instructions, may cause harmful 

interference to radio or television 

reception, which can be determined 

by turning the equipment off and 

on, the user is encouraged to try to 

correct the interference by one or 

more of the following measures:
• 

Reorient or relocate the receiving 

antenna.

• 

Increase the separation between 

the equipment and the receiver.

• 

Connect the equipment into an 

outlet on a circuit different from 

that to which the receiver is 

connected.

• 

Consult the dealer or an 

experienced radio/TV technician 

for help.

Operation is subject to the following 

two conditions: (1) this device may 

not cause interference and (2) this 

device must accept any interference, 

including interference that may cause 

undesired operation of the device.

Summary of Contents for VCX1525

Page 1: ...visit www dimplex com 7209350100R07 IMPORTANT SAFETY INFORMATION Always read this manual first before attempting to install or use this fireplace For your safety always comply with all warnings and sa...

Page 2: ...emphasize CAUTION Procedures and techniques which if not carefully followed will result in damage to the equipment WARNING Procedures and techniques which if not carefully followed will expose the us...

Page 3: ...uct Under Manufacturer s Warranty Contact us at www dimplex com customer_support For Troubleshooting and Technical Support OR Toll Free 1 888 DIMPLEX 1 888 346 7539 Monday to Friday 8 00 a m to 4 30 p...

Page 4: ...nctions Disconnect power at the service panel and have the heater inspected by a reputable electrician before reus IMPORTANT INSTRUCTIONS ing Do not operate any unit with a damaged cord or plug or if...

Page 5: ...fit contact a qualified electrician to install the proper outlet Always plug heaters directly into a wall outlet receptacle Never use with an extension cord or relocatable power tap outlet power strip...

Page 6: ...residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio...

Page 7: ...circuit will be required if after installa tion the circuit breaker trips or the fuse blows on a regular basis when the heater is operating Ad ditional appliances on the same circuit may exceed the cu...

Page 8: ...face such as a ta bletop to ensure adequate space for heat exhaust from the bottom of the fireplace Figure 3 3 With a wall stud finder locate the center of the wall stud drive a wood screw into the st...

Page 9: ...for mounting the fire place 7 With the glass assembly tak en off mount the firebox onto the two mounting screws 8 Mark position of hole H 9 Remove fireplace from wall 10 Install drywall anchor into dr...

Page 10: ...allation including the thickness of dry wall is required Make sure there is enough clearance for the cable coming out from the bottom of the fireplace NOTE Where there are close tolerances involved in...

Page 11: ...ove the outer jacket and strip the individual conductor from the end 5 Loosen the screw securing the junction box cover and remove the cover 6 Take the cables out from the junction box loosen the two...

Page 12: ...in Figure 4 Bathroom Installation This firebox must be protected by a GFI receptacle or circuit for bathroom use If receptacle is used it must be readily acces sible This unit is an electrical applia...

Page 13: ...n Add wood screws here Figure 8 Figure 9 Top Bracket Bottom Bracket WIRING M M ELEMENTS THERMOSTAT 3 POSITION SWITCH N L CUTOUT HEAT SWITCH FLICKER MOTOR LOWER LIGHTS BLOWER MOTOR INTEGRAL ON OFF R C...

Page 14: ...the unit is off B Heater On Off Switch The Heater On Off Switch sup plies power to the heater fan and the heater element When the switch is in the ON po sition the heater operates if the thermostat ca...

Page 15: ...h an integrated on off remote control NOTE Ensure that the fire place 3 Position Switch is set to the remote control setting To operate push the ON button to turn fireplace on push the OFF button to t...

Page 16: ...ints It is a good idea to replace all light bulbs at once if they are close to the end of their rated life Group replacement will reduce the number of times you will need to open the unit to re place...

Page 17: ...usting lightly with a clean dry cloth To remove fingerprints or other marks the glass can be cleaned with a damp cloth The glass should be completely dried with a lint free cloth to prevent water spot...

Page 18: ...imited warranty have been tested and inspected prior to shipment and subject to the provisions of this warranty Dimplex warrants such products to be free from defects in material and workmanship for a...

Page 19: ...sponsible for IN NO EVENT WILL DIMPLEX OR ITS DIRECTORS OFFICERS OR AGENTS BE LIABLE TO THE PURCHASER OR ANY THIRD PARTY WHETHER IN CON TRACT IN TORT OR ON ANY OTHER BASIS FOR ANY INDIRECT SPECIAL PUN...

Page 20: ...Mirror 5901180100RP Thermostat 2300150100RP Heater On Off Switch 2800070700RP Thermostat Control Knob 8801080100RP 3 Position Switch 2800071100RP Remote Control Receiver 3000380200RP Heater Assembly...

Reviews: