9
1. Locate the glass retention strip at the top of the front
glass (Figure 3).
2. Remove the securing screws on either side of the
retention strip.
3. Apply the suction cups to the glass at a comfortable
distance to allow for easily removing the front glass.
4. Gently tilt the glass forward, lift up and lift the glass out
of the unit.
5. Single units - Locate the 4 screws that secure the log-
set to the bottom of the unit (Figure 4) and remove the
logset.
!
NOTE:
The screws are recessed slightly into the em-
ber bed of the logset.
Double units - Depending on which side is not working
correctly, remove the corresponding logset to access
the LED controller, i.e. the left logs and lights are not
working remove the bottom left logs.
6. Locate the LED controller and disconnect the wiring
connections noting their original locations.
7. Remove the LED controller and install the new one.
8. Reassemble in the reverse order.
LED LIGHT ASSEMBLY REPLACEMENT
WARNING:
Disconnect power before attempting any
maintenance or cleaning to reduce the risk of electric
shock or damage to persons.
Tools required:
Phillips head screwdriver
Suction Cups
1. Locate the glass retention strip at the top of the front
glass (Figure 3).
2. Remove the securing screws on either side of the
retention strip.
3. Apply the suction cups to the glass at a comfortable
distance to allow for easily removing the front glass.
4. Gently tilt the glass forward, lift up and lift the glass out
of the unit.
5. Single units - Locate the 4 screws that secure the
logset to the bottom of the unit (2 on either end) and
remove the logset.
!
NOTE:
The screws are recessed slightly into the em-
ber bed of the logset.
Double units - Depending on which side is not working
correctly, remove the corresponding logset to access
the LED controller, i.e. the left logs and lights are not
working remove the bottom left logs.
6. The wiring for the light assembly is connected to the
LED controller located on the botton panel of the fire
-
box below the bottom logset. Disconnect the LED con-
nector for the light assembly from the LED controller
and attach a peice of string to the end that can be led
through the corner to pull the new LED light assembly
cord through.
7. Remove the light assembly by removing the two screws
located below the assembly and replace with new light
assembly.
8. Reassemble in the reverse order.
LED SCREEN REPLACEMENT
WARNING:
Disconnect power before attempting any
maintenance or cleaning to reduce the risk of electric
shock or damage to persons.
Tools required:
Phillips head screwdriver
5/16” (8 mm) socket wrench
Suction Cups
1. Locate the glass retention strip at the top of the front
glass (Figure 3).
2. Remove the securing screws on either side of the
retention strip.
3. Apply the suction cups to the glass at a comfortable
distance to allow for easily removing the front glass.
4. Gently tilt the glass forward, lift up and lift the glass out
of the unit.
5. Remove the electrical plug from the left hand side of
the unit ensuring that it cannot fall out of the back of the
unit (Figure 5)
6. Locate the 4 screws that secure the logset to the bot-
Figure 4
Approximate locations
of securing screws
(RH Double)
Approximate locations
of securing screws
(Single & LH Double)
Figure 5