background image

Dimensions

(millimetres)

Installation and Operating Instructions

Dimplex Wynford Fire
Model(s) : WYN20BR, WYN20BL & WYN20CH

08/18671/5   Issue 5

General

Unpack the heater carefully and retain the packaging for
possible future use, in the event of moving or returning the
fire to your supplier. Loose coals are packed separately
within the carton.
The heater is designed for use inset into a 407mm (16") or
457mm (18") wide by 559mm (22") high fireplace opening
see also section “Installation in a fire place opening”.
A 2kw fan heater discreetly positioned in the canopy of the
fire provides heating in cold weather. Switching allows half
or full heat.
Before connecting the heater check that the supply voltage
is the same as that stated on the heater.

Please note: Used in an environment where background
noise is very low, it may be possible to hear a sound which is
related to the operation of the flame effect. This is normal
and should not be a cause for concern.

Electrical

WARNING – THIS APPLIANCE MUST BE EARTHED

This heater must be used on an AC ~ supply only and the
voltage marked on the heater must correspond to the supply
voltage.
Before switching on, please read the safety warnings and
operating instructions.
For your convenience, the heater is fitted with a rewireable
plug incorporating a 13 amp fuse. In the event of replacing
the fuse in the plug supplied, a 13 amp fuse approved by
ASTA to BS1362 must be used.

Installation in a Fireplace Opening

At the rear of the fire, two adjustable supports are provided
for levelling the fire where the base of the fireplace opening
is raised above  the level of the hearth.
Adjust by removing the two screws holding each bracket in
position, then refit the bracket and the two screws in the
required position.
The surround may be removed to allow the fire to be fully
inset.
Note: The fire must be positioned a minimum distance of
500mm from a wall as indicated in 

Fig. 1

.

Fig. 1

IMPORTANT: THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE

Important Safety Advice

When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
electrical shock, and injury to persons, including the
following:
If the appliance is damaged, check with the supplier
before installation and operation.
Do not use outdoors.
Do not use in the immediate surroundings of a bath,
shower or swimming pool.
Do not locate the heater immediately below a fixed
socket outlet or connection box.
Do not cover the heater. Do not place material or
garments on the heater, or obstruct the air circulation
around the heater, for instance by curtains or furniture,
as this could cause overheating and a fire risk.
This appliance is not intended for use by children or
other persons without assistance or supervision if their
physical, sensory or mental capabilities prevent them
from using it safely. Children should be supervised to
ensure that they do not play with the appliance.

Caution: In order to avoid a hazard due to inadvertent
resetting of the thermal cut-out, this appliance must
not be supplied through an external switching device,
such as a timer, or connected to a circuit that is regularly
switched on and off by the utility.
Ensure that furniture, curtains or oth

er combustible

material are positioned no closer than 1 metre from the
heater.
In the event of a fault unplug the heater.
Unplug the heater when not required for long periods.
Although this heater complies with safety standards,
we do not recommend its use on deep pile carpets or
on long hair type of rugs.
The appliance must be positioned so that the plug is
accessible.
If the supply cord is damaged it must be replaced by the
manufacturer or service agent or a similarly qualified
person in order to avoid a hazard.

617

514

115

55

controls

128

Reviews: