background image

 

 

 

 

 

 

 

 

 

 

 

 

www.dimplex.com

Exploded Parts Diagram

Replacement Parts List

1.  Heater Assembly  . . . . . . . . . . . . . . . . . . . . . .

2203730300RP

2.  Power Supply . . . . . . . . . . . . . . . . . . . . . . . . .

2100250700RP

3.  Main Control Board Logs . . . . . . . . . . . . . . . .

3001840100RP

Media . . . . . . . . . . . . . . .

3001840200RP

4.  Power Cord  . . . . . . . . . . . . . . . . . . . . . . . . . .

4100190600RP

5.  Touchpad . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6700600100RP

6.  Thermistor  . . . . . . . . . . . . . . . . . . . . . . . . . . .

3001560900RP

7.  Flicker Motor. . . . . . . . . . . . . . . . . . . . . . . . . .3000240200KIT
8.  Flicker Rod XHD23. . . . . . . . . . . . . . . . . . . . .

5903090200RP

 XHD26 & XHD28

. . . . . . . . . . . . .

5903090100RP

9.  Flame LED Strip XHD23  . . . . . . . . . . . . . . . .

3001850300RP 

  XHD26 & XHD28

 . . . . . . . .

3001850100RP

10.  Flame Base LEDs (Log Models)  . . . . . . . . . .

3001880100RP

11.  Media LED Strip XHD23G . . . . . . . . . . . . . . .

3001570100RP

XHD26G

 . . . . . . . . . . . . . . .

3001570700RP

XHD28G

 . . . . . . . . . . . . . . .

3001570300RP

12.  Flame Screen XHD23  . . . . . . . . . . . . . . . . . .

5902580400RP

XHD26

 . . . . . . . . . . . . . . . . . .

5902580500RP

XHD28

 . . . . . . . . . . . . . . . . . .

5902580600RP

13.  Logset XHD23L . . . . . . . . . . . . . . . . . . . . . . .

0442330100RP

 XHD26L

 . . . . . . . . . . . . . . . . . . . . . . .

0442220100RP

 XHD28L

 . . . . . . . . . . . . . . . . . . . . . . .

0442300100RP

14.  Media Tray XHD23G  . . . . . . . . . . . . . . . . . . .

0442320100RP

 XHD26G

 . . . . . . . . . . . . . . . . . . .

0442280100RP

 XHD28G

 . . . . . . . . . . . . . . . . . . .

0442310100RP

15.  Medium Ice Chunks (Media Models) . . . . . . .

1400150100RP

16.  Large Ice Chunks (Media Models) . . . . . . . . .

1400130400RP

17.  Front Glass XHD23  . . . . . . . . . . . . . . . . . . . .

5903150100RP

XHD26

 . . . . . . . . . . . . . . . . . . . .

5903070100RP

XHD28

 . . . . . . . . . . . . . . . . . . . .

5903160100RP

18.  Remote Control  . . . . . . . . . . . . . . . . . . . . . . .

6700590200RP

19.  Mounting Hardware . . . . . . . . . . . . . . . . . . . .

9602100100RP

20. 

Felt Feet Pads

 . . . . . . . . . . . . . . . . . . . . . . . .

8600140101RP

12

17

1

2

3

4

10

7

13

8

9

5

6

19

18

Summary of Contents for XHD23G

Page 1: ...XX 6909850XXX 6909970XXX 7401050100R00 IMPORTANT SAFETY INFORMATION Always read this manual first before attempting to service this firebox For your safety always comply with all warnings and safety i...

Page 2: ...owed will expose the user to the risk of fire serious injury or death Operation 3 Exploded Parts Diagram 6 Replacement Parts List 6 Wiring Diagram 7 Accessing Top Components 8 Accessing Bottom compone...

Page 3: ...control panel to the right side of the white line to activate the icons The selected setting displays on the left side of the panel A multi function IR infrared remote control also is provided The rem...

Page 4: ...nge is 62o 78o F 17o 26o C This feature is active whenever the heat is enabled Disable Heat Using the manual controls press the Heat and Temp buttons at the same time and hold for 2 second to disable...

Page 5: ...lay will show b3 b1 b2 respectively High Low Medium G Flame Press to turn the flame effect On Press again to turn the flame effect Off H Timer Press multiple times to change the sleep timer by 0 5 hr...

Page 6: ...LEDs Log Models 3001880100RP 11 Media LED Strip XHD23G 3001570100RP XHD26G 3001570700RP XHD28G 3001570300RP 12 Flame Screen XHD23 5902580400RP XHD26 5902580500RP XHD28 5902580600RP 13 Logset XHD23L 04...

Page 7: ...7 Wiring Diagram Logset or Media Bed LEDs On log models only...

Page 8: ...the top cover flat so that the attached components are acces sible Accessing Bottom components Tools Required Phillips head screwdriver WARNING If the firebox was operating prior to servicing allow a...

Page 9: ...ving parts by securing wires in cable ties or electrical tape 5 Reassemble the firebox Main Control Board Replacement Tools Required Phillips head screwdriver Pliers WARNING If the firebox was operati...

Page 10: ...ead screwdriver WARNING If the firebox was operating prior to servicing allow at least 10 minutes for the heating elements to cool off to avoid accidental burning of skin WARNING Disconnect power befo...

Page 11: ...ect power before attempting any maintenance to reduce the risk of electric shock or injury to persons 1 Follow the instructions for accessing the bottom components on pages 8 9 2 Locate the plastic LE...

Page 12: ...curing wires in cable ties or electrical tape 4 Drop the cable for the old thermistor as well as the wire of the new thermistor down at the same location as the old thermistor so that they will be acc...

Page 13: ...replaced Change batteries see Maintenance section Defective remote control Replace remote control Defective touchpad Replace touchpad Appearance Log set dim or not glowing Loose connection Check wiri...

Page 14: ...cient space around the firebox Install feet if nec essary Buildup of dust debris Ensure that the exterior intake louvers and firebox cavity are free of dust debris Defective heater assembly Replace he...

Reviews: