8
9
Installation
Installation
Mounting
1.
If applicable, carefully pour and
evenly distribute the supplied media
in the media tray of the firebox.
Media
Tray
2a.
If installing into a Dimplex mantel,
first check to see if there are holes
in the side panels near the top as
shown below. If so, align the front
of the firebox (without front glass
installed) with the front face of the
mantel. Install provided screws
into the front holes on the inside
faces of the firebox. The screw will
line up with the hole in the mantel,
securing it in place.
Holes in
side panels
2b.
If installing into a custom mantel,
or into an existing opening,
secure the firebox by inserting
an appropriate screw through
either the front hole, or back hole
on the inside face of the firebox,
depending on which location
is more appropriate for the
installation.
Grounding Instructions
This product must be grounded. If it
should malfunction or break down,
grounding provides a path of least
resistance for electric current to reduce
the risk of electric shock. This product
is equipped with a cord having an
equipment-grounding conductor and a
grounding plug.
The plug must be plugged into an
appropri ate outlet that is properly
installed and grounded in accordance
with all local codes and ordinances.
DANGER
: Improper connec tion of
the equipment-grounding conductor can
result in a risk of electric shock. Check with
a qualified electrician or serviceman if you
are in doubt as to whether the product is
properly grounded. Do not modify the plug
provided with the product – if it will not fit
the outlet, have a proper outlet installed by
a qualified electrician.
Front
Back
If there are no holes on the side panels
of the mantel, remove the screw on the
back bottom flange most convenient
for securing, and use the L-bracket
(provided) to secure the firebox to the
mantel.