Instruction Manual
SAFELINE VARIO Diagnostics
17
2 Rack-Diagnostics
2.5.
Status information
In section 4 the status information of a selected module in area 2 is displayed.
The image of the status information is module-dependent.
2.5.1.
Status information central module ZMV
Status information ZMV
In the left panel, the following states are represented.
The boxes are checked, if the conditions are met.
SK1 - SK8
Conditions for safety circuit 1…. Safety circuit 8 is met.
ZH1 - ZH2
Conditions for two-hand control 1/2 are met.
MODS1 - MODS2
an output on the Operating mode selector (MODE SLCT) is set.
System OK
SL VARIO is working properly.
IO1+IO2:CLK
IO1 IO2 and are configured as clocked outputs.
IO3+IO4:CLK
IO3 and IO4 are configured as clocked outputs.
RTDS
Acknowledging of triggered Speed monitoring is due.
RTNI (S)
Release for network input information is set.
RTNI (R)
Release of network input information is reset.
RTSM
Acknowledgment of the reclosing lockout at safety mats is due.
RTSK
Acknowledgment of the safety circuit error message
and the latch error message is due.
RTFB