15
©
Dinel, s.r.o. CLM–70
10 .
s
etting
the
leVel
meter
UNITS
LEVEL:
mm
DISPLAY:
%
TEMPERATURE
°C
STARTING
Dinel
®
The level meter is controlled by
3 buttons
located on the re
-
movable DM-70 display module (see the Control Units chapter,
p. 14).
Saving of values is indicated by the word
“SAVED”
at the display
bottom (see Fig.). Values that have not been confirmed with the
ESC
OK
www.dinel.cz
Ultrasonic Level Meter ULM-70
ESC
OK
1745
mm
button
will not be saved!
After inactivity lasting 5 min
-
utes, the level meter automatically goes back to the measuring
mode. If the password is active, the level meter locks besides.
No
changes in settings are possible to be made after locking!
When attempting to edit, “NO PASSWORD” appears on the dis-
play. How to unlock, see p. 20.
After connecting the supply voltage, the manufacturer's logo
and the text
“Starting”
appear on the level meter display. Then, the level meter goes into the
measuring mode, and the actually measured value is displayed.
MIN CAPACITY (MAX CAPACITY)
Here, the CAPACITY range (in the
CAPACITY
line), within which the level meter should meas
-
ure, must be set. The output current range (the
OUTPUT
line) of 4 mA/20 mA output is then
assigned to this range. And the value shown on the meter display (
DISPLAY
line).
In the upper right corner below the sign “
ACTUAL CAPACITY
”, the value of the currently meas-
ured level is displayed.
ACTUAL CAPACITY: current meas-
ured capacity
CAPACITY: definition of the min/max
capacity
DISPLAY: the value show on the
display
BASIC SETTINGS
SERVICE
DIAGNOSTIC
CLONE SETTINGS
PASSWORD
INFO
SAVED
UNITS
CAPACITY:
PF
DISPLAY:
%
SAVED
STARTING
BASIC SETTINGS
SERVICE
DIAGNOSTIC
CLONE SETTINGS
PASSWORD
LANGUAGE
INFO
MIN CAPACITY
MAX CAPACITY
UNITS
DAMPING
SENSITIVITY
TEACHING
MIN
ACTUAL CAPACITY
023.56 pF
OUTPUT:
04.00 mA
CAPACITY:
013.33 pF
DISPLAY:
00000 %
MAX
OUTPUT:
20.00 mA
CAPACITY:
157.77 pF
DISPLAY:
00100 %
MIN
CAPACITY
MAX
CAPACITY
UNITS
DAMPING
SENSITIVITY
TEACHING
10 .1 .
B
asic
settings
After the first start of the level meter, the basic configuration
(setting of the measuring range, selecting units and possible
damping) must be performed. The settings are accessible in
the basic menu by pressing the
ESC
OK
www.dinel.cz
Ultrasonic Level Meter ULM-70
ESC
OK
1745
mm
button under “BASIC SET
-
TINGS”.
ACTUAL
CAPACITY
023.56 pF
Summary of Contents for CLM-70