19
©
Dinel, s.r.o. CLM–70
1.
Press the
ESC
OK
www.dinel.cz
Ultrasonic Level Meter ULM-70
ESC
OK
1745
mm
button to enter the menu; select “CLONE SETTINGS
”. To copy the settings
from the level meter body to the display module, select “SENSOR
→
DISPLAY MODULE”.
To transfer the settings from the display module to another level meter, select “DISPLAY
MODULE
→
SENSOR”.
2.
Press the
ESC
OK
www.dinel.cz
Ultrasonic Level Meter ULM-70
ESC
OK
1745
mm
button to run the selected mode, “NOW CLONING” appears on the display
during transfer
.
3.
When the process is complete, “DONE” appears in the display centre. Then, it is possible to
press the
ESC
OK
www.dinel.cz
Ultrasonic Level Meter ULM-70
ESC
OK
1745
mm
button again and exit the mode as well as the menu.
BASIC SETTINGS
SERVICE
DIAGNOSTIC
CLONE SETTINGS
PASSWORD
LANGUAGE
INFO
CLONE SETTINGS
SENSOR
DISPLAY
MODULE
DISPLAY
MODULE
SENSOR
CLONE SETTINGS
SENSOR
MODULE
DISPLAY
MODULE
DISPLAY
SENSOR
CLONE SETTINGS
This mode is for
copying the
CLM–70 level meter (body)
configuration
to the DM–70 display
module (display) and vice versa. Then, the display module can be removed from the level
meter body, and its settings can be transferred to the other level meter body.
The “CLONE SETTINGS” mode transfers all data except the “TEACHING” mode settings and
the HART
®
protocol configuration.
10 .3 .
a
dditional
functions
Additional functions include modes for copying settings or detecting the actual loop cur
-
rent. Further, they include password-based locking of modification and the level meter (dis-
play module) version information. All these functions are accessible from the main menu.
DIAGNOSTIC
CAPACITY:
Displays the actual value of the capacity that the sensor is currently measuring.
BASIC SETTINGS
SERVICE
DIAGNOSTIC
CLONE SETTINGS
PASSWORD
LANGUAGE
INFO
CAPACITY
CURRENT
CAPACITY
CURRENT
BASIC SETTINGS
SERVICE
DIAGNOSTIC
CLONE SETTINGS
PASSWORD
LANGUAGE
INFO
ON DISPLAY:
YES
– Diagnostics value (CAPACITY or CURRENT) is displayed on the main screen.
NO
– The standard measured value as set in the BASIC SETTINGS, MIN/MAX – DISPLAY is
displayed on the main screen.
SET VALUE:
Set the current to a fixed value (3.75 mA – 4mA – 12mA – 20mA – 22mA –
MEASUR.). If the MEASUR. option is selected, the current corresponds to the
measured value.
CURRENT:
Displays the actual value of the output current flowing through the loop
The SET VALUE option can be used to diagnose the connected evaluation device. If
the current is set to a fixed value, “FIXED OUTPUT” is displayed on the main display,
and the text “FIXED” is displayed in the SET VALUE section.
CAPACITY
012.20 pF
ON DISPLAY: YES
CURRENT
17.30 mA
ON DISPLAY:
YES
SET VALUE:
MEASUR.