background image

22

© 

Dinel, s.r.o.      DLM–35

   

18 .  Packings, shipping and storage

The  device  DLM–35  is  packaged  in  a  polyethylene  bag,  and  the  entire  consignment  is  placed  into 

a cardboard box. A suitable filler material is used in the cardboard box to prevent mechanical damage 

during transport. Remove the device from the packaging only just before using, thereby protecting it from 

potential damage.
A forwarding company will be used to ship goods to the customer. Upon prior agreement, ordered goods 

can be picked up in person at company headquarters. When receiving, please check to see that the 

consignment is complete and matches the order, or to see if any damage has occurred to the packaging 

and device during transport. Do not use a device clearly damaged during transport, but rather contact the 

manufacturer in order to resolve the situation.
If the device is to be further shipped, it must be wrapped in its original packaging and protected against 

impact and weather conditions. 
Store the device in its original packaging in dry areas covered from weather conditions, with humidity 

of  up  to  85 %  without  effects  of  chemically  active  substances.  The  storage  temperature  range  is  

-10 °C to +50 °C.

All level meters except the type variant DLM–35_–50 are given protective covers at ends 

of electrodes (longer than 100 mm) and of reference tubes in order to prevent damage to 

electrode and tubes, tearing of the package or injury of persons handling them. Remove 

the cover prior to putting into operation.

Factory default

4 mA (0V)

electrode system capacity in open space

20 mA (10V)

capacity 1nF (± 20%)

This setting can not be used directly for level measurement, but it is always necessary to make 

setting according to chapter 9.
In special cases (e.g.: by using reference electrode) sensor settings can be agreed with the 

manufacturer.

Summary of Contents for DLM-35

Page 1: ...ed in this manual before the first use of the level meter Keep the manual at a safe place The manufacturer reserves the right to implement changes without prior notice pr myslov elektronika Capacitive...

Page 2: ...Control elements 11 8 Function and status indication 11 9 Settings 12 10 Order code 14 11 Correct specification examples 14 12 Accessories 15 13 Safety protections compatibility and explosion proof 15...

Page 3: ...iT XiMT available DLM are offered in variants with various types of process con nection metric and pipe thread pressure thread NPT 1 Basic description To ensure maximum safety of control processes we...

Page 4: ...30 Uncoated rod electrode used for level measurement of bulk solids cement flour sand plastic granulate and electrically non conductive liquids vegetable oil diesel fuel petrol Maximum electrode lengt...

Page 5: ...PT 3 4 All dimensions are in mm 64 22 35 16 36 6 5 E100 E1000 10 10 8 15 42 DLM 35_ 20 DLM 35_ 21 22 25 DLM 35_ 30 DLM 35_ 31 thread E100 E1000 10 10 6 46 46 E100 E3000 E100 E3000 8 Measuring electrod...

Page 6: ...r M12 6 5 12 18 12 20 15 20 M12 13 Variant H with cable gland for protected hoses for using in an outdoor area or in area with increased moisture Variant V with plastic cable gland with spiral relief...

Page 7: ...with steel armouring For level measurement of material in plastic and glass vessels by level meter without reference tube is necessary to connect grounding screw at housing with auxiliary electrode wh...

Page 8: ...th reference tube DEEP METAL AND CONCRETE HOPPERS For types DLM 35_ 50 connection to the armouring E electrode length mm select so that the end of the electrode would be at least 20 mm under the lowes...

Page 9: ...cable for the Xi XiT XiM XiMT variations must be selected with respect to the maximum permitted parameters usually inductance and capacity of the outside intrinsically safe circuit of supply units IRU...

Page 10: ...he shielding on the side of the power source 7 Control elements Cable gland or connector Orange LED Sensitive spot Sensitive spot Green LED spot input to setting mode direct setting to value 4mA 0V de...

Page 11: ...dicators STATE and RUN it is possible to put away the magnetic pen The LED indicator STATE will briefly flash 3x to confirm the setting of the limit Setting the upper limit 20 mA 10 V Direct 1 Fill th...

Page 12: ...irect 1 Bring the level in the tank to a known determinable level best when close to the maximum measured level 2 Touch the magnetic pen for approx 3 seconds on the sensitive spot of the level meter A...

Page 13: ...ectrode length 200mm process connection DLM 35 electrode length in mm E type of output I current 4 20 mA U voltage 0 10 V connection method A short stainless steel gland cable length B plastic threade...

Page 14: ...es for safety and electromagnetic compatibility Special conditions for safe use of variant DLM 35Xi XiT XiM XiMT Level meters DLM 35Xi XiT XiM XiMT are intended for connection to approved spark safe p...

Page 15: ...g operation and maintenance of the DLM 35 level meter has to be carried out in accordance with this instruction manual the provisions of regulations in force regarding the installation of electrical e...

Page 16: ...T 2 4 Ga Gb II 1 D Ex ia II T C 2 I C 120 Da Db FTZ 16 ATEX 0138X No ______ E_____ Cable __m II 1 G Ex ia IIB T4 Ga II 1 D Ex ia II T C I C 120 Da FTZ 16 ATEX 0138X 0 V U 1 bn 3 bu 0 V U 1 bn 3 bu 0...

Page 17: ...t 0 5 C a 4 7 1026 760 01 Zl n Czech Republic w t tek pro varianty DLM 35XiM __ __ I _ __ t tek pro varianty DLM 35XiMT __ __ I _ __ No ______ DLM 35XiM __ __ I _ __ E_____ Cable __m No ______ DLM 35X...

Page 18: ...dielectric strength 47 nF 350 V AC Ambient temperature range 40 85 C Protection type DLM 35_ _ _ C _ _ type DLM 35_ _ _ A B V H _ _ IP67 IP68 Maximum load resistance for current output at U 24 V Rmax...

Page 19: ...nits DLM 35XiMT Intrinsically safe high temperature explosion proof performance for use in mines with the occurrence of methane or coal dust I M1 Ex ia I Ma with intrinsically safe supply units Use ma...

Page 20: ...50 40 C 250 C 40 C 85 C 40 C 85 C DLM 35NT 20 30 40 C 300 C 40 C 200 C 40 C 85 C DLM 35NT 21 22 31 40 41 40 C 200 C 40 C 200 C 40 C 85 C DLM 35NT 25 40 C 200 C 40 C 200 C 40 C 85 C DLM 35NT 50 40 C 2...

Page 21: ...LM 35NT 25 2 0 MPa 20 bar 2 0 MPa 20 bar 2 0 MPa 20 bar 2 0 MPa 20 bar 2 0 MPa 20 bar DLM 35NT 50 0 1 MPa 1 bar 0 1 MPa 1 bar 0 1 MPa 1 bar 0 1 MPa 1 bar 0 1 MPa 1 bar DLM 35Xi XiM 20 30 5 MPa 50 bar...

Page 22: ...r to resolve the situation If the device is to be further shipped it must be wrapped in its original packaging and protected against impact and weather conditions Store the device in its original pack...

Page 23: ...r o U Tescomy 249 760 01 Zl n Czech Republic Phone 420 577 002 002 Fax 420 577 002 007 E mail sale dinel cz www dinel cz Find the updated version at www dinel cz version 08 2017 industrial electronics...

Reviews: