HLM–35
©
Dinel, s.r.o.
16
20. Technical specifications
Used materials
Sensor part
Variants
Standard material
Housing
All types
stainless steel W.Nr. 1.4404 (AISI 316L)
End of sensor
All types
stainless steel W.Nr. 1.4301 (AISI 304)
Membrane
HLM–35_–C_- _- _- _- _- _ _ _ _
HLM–35_–S_- _- _- _- _- _ _ _ _
ceramic Al2O3 96%
stainless steel 1.4404
Gasket O-rings
All types
FPM (Viton)
Cable terminal
HLM–35_–_ _- _- _- A- _- _ _ _ _
HLM–35_–_ _- _- _- B- _- _ _ _ _
HLM–35_–_ _- _- _- V- _- _ _ _ _
HLM–35_–_ _- _- _- H- _- _ _ _ _
stainless steel W.Nr. 1.4301 (AISI 304)
plastic PA / NBR
plastic PA / NBR
plastic PA / NBR
Connector M12
HLM–35_–_ _- _- _- C- _- _ _ _ _
nickel-plated brass
Technical specifications
performance
non-explosive areas
Supply voltage
HLM–35_–_ _- _- I- _- _- _ _ _ _
HLM–35_–_ _- _- U- _- _- _ _ _ _
12 ... 34 V DC
12 ... 34 V DC
Current output
Voltage output
HLM–35_–_ _- _- I- _- _- _ _ _ _
HLM–35_–_ _- _- U- _- _- _ _ _ _
4 ... 20 mA
0 ... 10 V
Consumption
(eg no-load output)
HLM–35_–_ _- _- U- _- _- _ _ _ _
max. 8 mA
Permissible overload
1,5x range
Basic accuracy (nonlinearity, hysteresis, repeatability)
0.5% of range
(adjustable variant 0.2%)
Long-term stability
0,3 % / year
Temperature error for zero and range in the range 0 ... + 50 ° C
max. 0,04% / K
Temperature compensation range
0 ... +50°C
Operating temperature range (medium temperature)
-20 ... +70 °C
Max. load resistance of current output (at U = 24 V DC)
R
max
= 600
Ω
Min. load resistance of voltage output
R
min
= 5 k
Ω
Protection class
typ
HLM–35_–_ _- _- _- C- _-
_ _ _ _
typ
HLM–35_– _- _- _- (A,B,V,H)- _- _ _ _ _
IP67
IP68
Cable
typ HLM–35_–_ V- _- I- _- _- _ _ _ _
typ HLM–35_–_ V- _- U- _- _- _ _ _ _
typ HLM–35_–_ K- _- I- _- _- _ _ _ _
typ HLM–35_–_ K- _- U- _- _- _ _ _ _
PVC 2 x 0,75 mm
2
PVC 3 x 0,5 mm
2
PE 2 x 0,25 mm
2
with capillary
PE 3 x 0,25 mm
2
with capillary
Weight
sensor
cable (1 m)
190 g
60 g