background image

HLM–35      

© 

Dinel, s.r.o.

6

Variant "H" with terminal for protected

 

hoses – for use in outdoor environments or 

in areas with increased moisture.

Variant "V" with plastic terminal with

 

spiral relief – in case of increased 

mechanical strain on the cable.

(63)

Note. Values in brackets apply for version with the capillary (CK and SK)

5 .  Installation and putting into operation

This procedure has the following three steps:

•  Mechanical mounting - see Chapter 6

•  Electrical connection - see Chapter 7

•  Settings - see Chapter 8

Variant "A" with short

 

stainless steel terminal

Variant "B" with plastic

 

threaded terminal

Variant "C" with

 

connector M12

(

27

)

Spiral relief

protective hose

(ø 13 mm)

Summary of Contents for HLM-35

Page 1: ...vel meter read the instructions in this manual and keep it carefully The manufacturer reserves the right to make alterations without a prior notice Hydrostatic level meters HLM 35 Hydrostatic level me...

Page 2: ......

Page 3: ...tion and status indication 9 10 Connection examples 10 11 User adjustable measuring ranges 12 12 Examples of markings for a variant with user settings 12 13 Order code 13 14 Correct specification exam...

Page 4: ...es in curred by either direct or indirect damage and the expenditure incurred during the installation or the use of the sensor In order to ensure maximum safety of control processes we have defined th...

Page 5: ...ter membrane Pressure equalisation via a capillary HLM 35N SV measuring range 1 100 m H2O arbitrary standard measuring range can be custom set in 10 cm increments In case of the variant with an option...

Page 6: ...on the cable 63 Note Values in brackets apply for version with the capillary CK and SK 5 Installation and putting into operation This procedure has the following three steps Mechanical mounting see C...

Page 7: ...ble it is necessary to ground the cable on the side of the power source for the event of a possible lightning electrical discharge in the vicinity of the sensor In the event that the level meter is in...

Page 8: ...in no 1 the negative pole 0 V to the blue wire BU or connector pin no 3 and the output voltage Uout to the black wire BK or connector pin no 4 Connection diagrams are provided in the figures below X C...

Page 9: ...ue The setting progress is indicated by the or ange STATE indicator The correct level measurement function is indicated by the green RUN indicator Cable gland or connector Top view of the level meter...

Page 10: ...t to the unit PDU 4xx P output 4 20 mA using junction box NB In the case using a connection box with integrated overvoltage protection the sensor needs to be connected to the bottom series of terminal...

Page 11: ...a connection box with integrated overvoltage protection the sensor needs to be connected to the bottom series of terminals This series of contacts is marked by label SENSOR cable shield cable shield...

Page 12: ...nd for CV and SV M Settings using the magnetic pen 0100 measuring range 10 the maximum output current can be set in the range of 5 to 10 m see table User adjustable measuring ranges HLM 35N SK M27 I B...

Page 13: ...20 mA U voltage 0 10 V CONNECTION METHOD A stainless steel cable gland for CV and SV B plastic threaded cable gland for CV CK SV and SK C connector socket not included with sensor recommended type see...

Page 14: ...term overvoltage Protection against dangerous contact is provided by low safety voltage according to 33 2000 4 41 Electromagnetic compatibility is provided by conformity with standards EN 55011 B EN 6...

Page 15: ...maintenance It is forbidden to make any changes or interventions on the HLM 35 level meter without the consent of the manufacturer Any repairs must only be carried out by the manu facturer or a servic...

Page 16: ...12 34 V DC 12 34 V DC Current output Voltage output HLM 35_ __ _ I _ _ ____ HLM 35_ __ _ U _ _ ____ 4 20 mA 0 10 V Consumption eg no load output HLM 35_ __ _ U _ _ ____ max 8 mA Permissible overload 1...

Page 17: ...When receiving please check to see that the consignment is complete and matches the order or to see if any damage has occurred to the packaging and device during transport Do not use a device clearly...

Page 18: ...HLM 35 Dinel s r o 18 Notes...

Page 19: ......

Page 20: ...Dinel s r o U Tescomy 249 760 01 Zl n esk republika Tel 420 577 002 002 E mail obchod dinel cz www dinel cz Aktu ln verzi n vodu naleznete na www dinel cz verze 2017 05 2020...

Reviews: