And it also can be changed and saved by “curve chooses”.
Click „Start‟,the whole station starts to heating,and the working curve is showing the current
parameter
,
and it will also clear the previous curve showed on screen.The whole heating will
complete until the upper setting temperature or the upper part of the heating rate is zero,and just
the machine stops running,with the alarm ringing, if the cooling vacuum interface has been set up
within the cooling and vacuum state, then these two output also work.if click „stop‟ in the normal
operation process, the machine will stop heating.And click ‟Keep‟, the button appears as
flashing,showing the machine entering the temperature kept status,and the whole heating
temperature will keep the current temperature constant working,until click the button again,it will
return to normal heating.
Advanced Parameters have been set well, and they are not needed to change.The machine can
monitor the speed of the cooling fans, and also can set the lowest speed.When the cooling fans
stop running or the speed lower than the setting one, and the collection of hot air up and down the
value of the actual temperature is higher than 300 degrees, the heating system will stop heating
immediately. System can automatically set the early warning time, such as early warning: 10
second, showing that the buzzer alarm will sound when there is 10s left heating.
When machine
into the cooling state, in the main interface will show the corresponding fault tips! It can help the
operator to quickly determine the point of failure!
When Click the „Back‟, it wills pop-up function selection screen.it can choose the „English‟
interface.
NOTE:
When it alarm because of stoppage, all founction buttons are in locked
state! After manageing the stoppage and starting up, it can recover to
normal state!
七
、
usual temperature parameters as follows: