16
When Click the „Back‟
, it wills pop-up function selection screen.it can choose the
„English‟
interface.
NOTE:
When it alarm because of stoppage, all function buttons are in locked state! After
managing the stoppage and starting up, it can recover to normal state!
七
、
usual temperature parameters as follows:
Lead temperature curve welding
41*41 BGA welding temperature setting
Preheating
Constant
Heating
Welding
1st
Welding
2nd
Reduction
Upper
heating
160
185
210
220
225
0
Constant
time
30
30
35
40
20
0
Bottom
heating
165
190
215
225
230
0
Constant
time
30
30
35
40
70
0
IR
preheating
110
120
130
140
150
0
Constant
time
30
30
35
40
70
0
Speed rate
2
2
2
2
2
0