English  3

Dino-Lite User manual

2.  Please use a USB 2.0 port that is fully powered. Some USB ports 

on portable computers do not supply sufficient power.

3.  The driver will be automatically installed. Please WAIT until 

the notification appears: ‘Device driver software installed 
successfully’.

4.  Now start DinoCapture 2.0 by double clicking on the desktop icon.

5.  The LED lights should go on and an image should appear in 

DinoCapture. If this is not the case, refer to the frequently-
asked-questions (FAQ) on 

www.dino-lite.eu

Hardware features

1.  At the center of the device, the adjustable dial is used to  

set the focus. The focus of the image depends on the distance 
to the object. Once you have focused on the object, you can 
read the magnification rate achieved from the number next to  
 

2.  The models in the AM/AD 411X series feature a magnification 

lock. The magnification lock is particularly useful for repetitive 
inspection at a given level of magnification.

3.  Dino-Lite models with the letter T in their product name have 

a Microtouch function at the cable end of the device. Touching 
this sensor will capture the current image or start/stop video 
recording (for usb-devices). On the Dino-Lite high speed real 
time models the Microtouch sensor can be used to switch the 
LEDs on/off (all models) or freeze the image (AM5116 models 
only).

4.  Models with the letter Z in their product name have a 

polarization function, that can be controlled by turning the 
adjustable cap.

5.  Models with the letter L operate at a longer working distance. 

These models only achieve focus at some distance from the 
object.

6.  The AD and Edge models have exchangeable front covers/

caps. Align the red lines on cap and frontend of the Dino-Lite to 

Summary of Contents for 411X Series

Page 1: ......

Page 2: ...ure software runs on computers with a Windows XP Windows Vista or Windows 7 8 operating system The DinoXcope software is designed to work with Apple Macintosh OS Important safety information Avoid tou...

Page 3: ...some systems Select Run or YES Choose the language you want for the DinoCapture 2 0 interface 3 Read the User License Agreement If you agree press Yes to continue or press no to stop the installation...

Page 4: ...rom the number next to 2 The models in the AM AD 411X series feature a magnification lock The magnification lock is particularly useful for repetitive inspection at a given level of magnification 3 Di...

Page 5: ...the macro zoom function Software interface DinoCapture Windows There are five key sections in the DinoCapture software 1 Menu bar 2 Image list tools 3 Preview window management bar 4 Tool bar 5 Previe...

Page 6: ...the selected picture s to a new message opened in your default e mail client Print print the selected picture Slideshow run a slideshow of the selected pictures Delete clean up the image thumbnail ga...

Page 7: ...ngth and click again to finish Continuous line Click and drag to form one section of distance click again to start another section Continue until the total desired distance is measured Double click to...

Page 8: ...will change to a pointing finger for selectable circles Click on each circle and the software will measure the distance Gridlines The pitch will match the magnification inputted Circle grid The pitch...

Page 9: ...read from the dial on the microscope Units Select the unit of measurement inch mil mm or um Calibration menu Select calibration create new calibration profile or open the calibration folder Barcode Re...

Page 10: ...een or press ESC Close window Allows you to close the current window Snapshot Take a picture Video recorder Start stop recording of a video Time Lapsed Video Create a series of images or videos taken...

Page 11: ...the annotation box will expand Write text within this box and press ENTER to start a new line When done left click anywhere in the preview window to save the annotation and exit the annotation box Fo...

Page 12: ...on that you read from the focus dial Make video Choose frame rate recording time quality and compression To stop recording manually use the ESC key Make time lapse video Choose capture interval number...

Page 13: ...selection window for drawing and measurement tools After selection click okay and use the tool on the live image 4 Open image If you open a stored image you will see a menu bar above it that allows yo...

Page 14: ...t accessories i e detachable caps extensions are not covered under warranty For warranty issues please contact the reseller or store where you bought the product Support If you have any problem or iss...

Page 15: ...No 7 102 817 B1 Germany Pat No 20 2006 001 409 8 Japan Pat No 3123176 Taiwan Pat No M302031 AnMo Electronics Corporation and its authorized representative in the EU IDCP BV declare that the apparatus...

Page 16: ......

Reviews: