3. pressure relief steps
⑴
close spray gun insurance
(
as the right chart
)
⑵
shut the power switch.
⑶
pressure control buttons will be set on place without pressure
(
black areas
)
potision.
⑷
open spray gun insurance and a 180-degree reversal.
⑸
paint barrels of the guns at the wall ,the deduction under the trigger ,the
equipment and piping in the pressures release.
⑹
close spray gun insurance .
(
as the right chart
)
⑺
return valve will be set in the vertical position ,all in the equipment may be
remnants from the pressure.
III day-to-day maintenance measures.
⑴
before each spraying ,check compliance with electricity .
⑵
Before each spraying, we must add seal oil into the mouth drop PSL 5-6.
⑶
after each spraying ,the equipment must be thoroughly cleaned and parts.
⑷
after each spraying ,pleas high-pressure hose coiled to prevent damage to tie.
⑸
If long-term storage does not work, should be used to protect the body fluid (blue
bottle), a bottle of protection against the bucket of water to dilute the protection of
the equipment, cycle, the role is to protect the equipment, spare parts from
corrosion, and the final Let a little lubrication equipment inhalation solution, and add
the PSL.
!
!
warning
!
!
in any equipment cleaning ,repair and maintenance
or before the middle of the break, and you must step
in accordance with the venting pressure relief .