DINO 105TL
16
-
Never use a lift alone. Make sure that there is always someone on the ground,
who can call for help in case of an emergency.
6 INSPECTIONS
The lift must be subjected to a
start-up inspection
before it is used for the first time and
before starting it up the first time after a major repair or modification work.
The lift must be subjected to a thorough
periodic inspection with related test drive
at
intervals of year.
The lift must be subjected to a thorough
periodic inspection with test drive
at intervals of
four years.
In connection with the periodic inspection the lift must be subjected to a
non-destructive
inspection/inspection disassembled
in general at intervals of ten (10) years from the
start-up date.
In addition, the lift much be
inspected
to the extent applicable after any exceptional
situation
For the inspection must be assigned an
expert inspection body
with documented
evidence of competence or an
expert with documented evidence
of competence.
A
protocol
must be drawn up of the executed inspections. The protocols of the start-up
and periodic inspections must be kept with the lift or its immediate proximity for at least five
years.
Carry out the inspections regularly basis throughout the service life of the lift.
The inspection must be carried out within twelve (12) months off the first or previous
inspection.
If the lift is used under extreme conditions, intervals between the inspections shall be
reduced.
The overall operating condition of the lift as well as the condition of the safety-related
control devices shall be established in the regular inspections. Particular attention shall be
paid to changes which affect the operational safety.
In connection with the regular inspection, it shall be established to what extent the lessons
and practical experience gained from the previous inspection can be implemented for even
better safety.
Regular inspections and service measures are described more thoroughly in the chapter
“Service- and maintenance”.
Summary of Contents for DINO 105TL
Page 2: ...DINO 105TL 2 ...
Page 3: ...DINO 105TL 3 ORIGINAL OPERATING INSTRUCTIONS Valid from serial number 10196 ...
Page 6: ...DINO 105TL 6 HYDRAULIC DIAGRAM 10189 81 23 1 NOTES 82 ...
Page 8: ...DINO 105TL 8 2 REACH DIAGRAM ...
Page 9: ...DINO 105TL 9 3 DIMENSION DRAWING ...
Page 35: ...DINO 105TL 35 o that the driving device is disconnected from the wheel ...
Page 38: ...DINO 105TL 38 18 3 LUBRICATION PLAN 1 2 3 4 5 5 6 7 8 10 9 11 12 ...
Page 41: ...DINO 105TL 41 ...
Page 53: ...DINO 105TL 53 19 1 1 SAMPLE OF INSPECTION PROTOCOL FOR THE ACCESS PLATFORM ...
Page 54: ...DINO 105TL 54 ...
Page 69: ...DINO 105TL 69 21 1 NOTES ...
Page 73: ...DINO 105TL 73 23 ELECTRIC DIAGRAM 105TL 10196 ...
Page 74: ...DINO 105TL 74 ...
Page 75: ...DINO 105TL 75 ...
Page 76: ...DINO 105TL 76 ...
Page 77: ...DINO 105TL 77 ...
Page 78: ...DINO 105TL 78 ...
Page 79: ...DINO 105TL 79 ...
Page 80: ...DINO 105TL 80 ...
Page 81: ...DINO 105TL 81 HYDRAULIC DIAGRAM 10189 ...
Page 82: ...DINO 105TL 82 23 1 NOTES ...