FAULT FINDING
FAULT
REMEDY
1. The electric motor does not start from the start button although the selector switch
is in position LCB or UCB
Emergency stop button is stuck.
Pull up the button and re-start the engine
with the start button.
One of the fuses F1, F2 or F3 has blown.
Replace the fuse (10A).
No mains supply (230VAC) to the selector
switch.
Check the extension cords, possible
distribution boards and fuses.
The fault current safety switch has tripped.
Reset the fault current safety switch.
Voltage supply to the switch OK, but no
transmission forward.
Check the operation of the selector switch
and replace it, if necessary.
Power input to the selector switch and
output from the switch are OK.
Check the operation of the engine control
contactor and thermo-relay as well as the
operation of the relays which control the
operation of the contactors.
2. None of the platform movements is operational though the electric motor is
running and the selector switch is in position LCB or UCB
Green signal light for outriggers is not lit.
Check operation of the safety limit switches
RK11, RK12, RK13 and RK14.
The green signal light for the outrigger limit
switches is lit, but the boom movements do
not operate.
Check the operation of the safety relay SR2
for the outrigger circuit.
Check, whether the fault is in the electric system or in the hydraulic system.
3. Support outriggers do not move
Boom does not rest on the transport
support.
Drive the boom onto the transport support
R3.
The selector switch is in wrong position.
Turn the selector switch Q1 to position LCB.
Limit switch on the boom support is not
closed.
Drive the boom onto the transport support
and check the operation of the limit switch
RK3.
Summary of Contents for DINO 105TL
Page 2: ...DINO 105TL 2 ...
Page 3: ...DINO 105TL 3 ORIGINAL OPERATING INSTRUCTIONS Valid from serial number 10196 ...
Page 6: ...DINO 105TL 6 HYDRAULIC DIAGRAM 10189 81 23 1 NOTES 82 ...
Page 8: ...DINO 105TL 8 2 REACH DIAGRAM ...
Page 9: ...DINO 105TL 9 3 DIMENSION DRAWING ...
Page 35: ...DINO 105TL 35 o that the driving device is disconnected from the wheel ...
Page 38: ...DINO 105TL 38 18 3 LUBRICATION PLAN 1 2 3 4 5 5 6 7 8 10 9 11 12 ...
Page 41: ...DINO 105TL 41 ...
Page 53: ...DINO 105TL 53 19 1 1 SAMPLE OF INSPECTION PROTOCOL FOR THE ACCESS PLATFORM ...
Page 54: ...DINO 105TL 54 ...
Page 69: ...DINO 105TL 69 21 1 NOTES ...
Page 73: ...DINO 105TL 73 23 ELECTRIC DIAGRAM 105TL 10196 ...
Page 74: ...DINO 105TL 74 ...
Page 75: ...DINO 105TL 75 ...
Page 76: ...DINO 105TL 76 ...
Page 77: ...DINO 105TL 77 ...
Page 78: ...DINO 105TL 78 ...
Page 79: ...DINO 105TL 79 ...
Page 80: ...DINO 105TL 80 ...
Page 81: ...DINO 105TL 81 HYDRAULIC DIAGRAM 10189 ...
Page 82: ...DINO 105TL 82 23 1 NOTES ...