FAULT REMEDY
7. Boom cannot be lifted
Refer to item 5.
Electric valve open.
Remedy as instructed above in conjunction with
the seizure of the electric valve spool.
The lift turns as the lifting movement is
activated.
Solenoid valve is stuck in turning position.
Wash carefully the spool and the block.
8. Telescope movement does not operate
Refer to item 5.
Check that the solenoid valve of the telescope is
not stuck in the centre (open) position.