35
Special function
PARAMETER Display Screen - A
PARAMETER Display Screen - V
Default
Range
UP SLOPE
F29
0.0s
(0.0 - 5.0)s
DOWN SLOPE
F30
2.0s
(0.0 - 8.0)s
TIG PULSE DELTA CURRENT
F23
-50%
(-100 ÷ 1000)%
TIG PULSE BALANCE
F25
0
(-40 ÷ 40)%
TIG PULSE FREQUENCY
F26
100.0Hz
(0.1 ÷ 500.0)Hz
SWS VOLTAGE THRESHOLD
F31
0
-30 - +30
WARNING:
•
It is possible to access editing of the
SPECIAL FUNCTIONS (Fx)
during welding.
•
Some of the values edited will be used immediately by the operator, while others will be active from when the next welding
task begins.
•
The
HOLD
function is not active within the
SPECIAL FUNCTIONS Menu (SET UP Fx)
.
2 - PRE-SETTING
TIG LIFT
„PI 3006.M PULS“ / „PI 4006.M PULS“ / „PI 4606.M PULS“ CONTROL PANEL
MENU K
Ey
ENCODER K
NOb
- SX
A
V
111 50.0
MENU K
Ey
Used to access the
PROCESS SELECTION Menu (PROCESS)
and subsequent menus, as
applicable.
ENCODER K
NOb
- SX
Adjust the value of the parameter
WELDING CURRENT
(
).
(continued)
„WF 793.M“ CONTROL PANEL
ENCODER K
NOb
- a
paRaMETER SElECTiON lED - a
paRaMETER D
iSplay
S
CREEN
- a
paRaMETER SElECTiON lED - V
paRaMETER D
iSplay
S
CREEN
- V
PARAMETER
DISPLAY
S
CREEN
- A
Displays the value of the parameter
WELDING CURRENT
(
).
PARAMETER SELECTION LED - A
The LED unit shows the
WELDING CURRENT
(
) switched on.
(continued)
Summary of Contents for DIX PI 3006.M PULS