4
Opening the packaging
The system essentially consists of:
•
DIX 3006.M PULS, DIX PI 4006.M PULS
or
DIX PI 4606.M PULS
weld unit.
•
Separately:
- WF 793.M wire-feeder unit (supplied separately).
- MIG-MAG welding torch (optional).
- Wire-feeder/welding power source interconnection cable
(supplied separately).
- Cooling modul for welding torch (optional).
- Trolley to carry it around (optional).
Perform the following operations on receiving the apparatus:
•
Remove the welding power source and all accessories and
components from the packaging.
•
Check that the welding apparatus is in good condition; other-
wise immediately inform the retailer or distributor.
•
Check that all the ventilation grilles are open and that there
is nothing to obstruct the correct air flow.
Installation and connections
The installation site for the system must be carefully chosen
in order to ensure its satisfactory and safe use. The user is re-
sponsible for the installation and use of the system in accord-
ance with the producer’s instructions contained in this manual.
Before installing the system the user must take into consider-
ation the potential electromagnetic problems in the work area.
In particular, we suggest that you should avoid installing the
system close to:
•
Signalling, control and telephone cables.
•
Radio and television transmitters and receivers.
•
Computers and control and measurement instruments.
•
Security and protection instruments.
Persons fitted with pace-makers, hearing aids and similar
equipment must consult their doctor before going near a weld-
ing power source in operation. The equipment’s installation
environment must comply to the protection level of the frame.
The welding unit is characterized by the following classes:
•
IP 23 S protection class indicates that the welding power
source can be used in both interior and exterior environ-
ments.
•
The “S” usage class indicates that the welding power source
can be employed in environments with a high risk of electri-
cal shocks.
This system is cooled by means of the forced circulation of air,
and must therefore be placed in such a way that the air may
be easily sucked in and expelled through the apertures made
in the frame.
Assemble the system in the following way:
•
Assemble the trolley.
•
Fixing the cooling unit to the trolley.
•
Fixing of the welding power source to the trolley and the cool-
ing unit (electrical and plumbing connections).
•
Fitting the feeder unit to the welding power source.
•
Connect up the welder to the mains.
•
Connect up the wire-feeder/welding power source intercon-
nection cable.
•
Connect up the welding cables.
Instructions for fitting the individual components / optional ex-
tras are contained in the relevant packaging.
Connection to the electrical supply
Connection of the welding power source to the user line
(electrical current) must be performed by qualified per-
sonnel.
Before connecting the welding power source to the mains
power supply, make sure that rated voltage and frequen-
cy correspond to those provided by the mains power sup-
ply and that the welding power source’s power switch is
turned to “O”.
Use the welder’s own plug to connect it up to the main pow-
er supply. Proceed as follows if you have to replace the plug:
•
3 conducting wires are needed for connecting the welding
power source to the supply.
•
The fourth, which is YELLOW GREEN in colour is used for
making the “GROUND” connection.
Connect a suitable load of normalised plug (3P+T) to the
power cable and provide for an electrical socket complete
with fuses or an automatic switch. The ground terminal
must be connected to the ground conducting wire (YEL-
LOW-GREEN) of the supply.
Table 2 shows the capacity values that are recommended for
fuses in the line with delays.
NOTE: Any extensions to the power cable must be of a suita-
ble diameter, and absolutely not of a smaller diameter than the
special cable supplied with the welding power source.
Usage norms
CONTROL APPARATUS (Fig. A)
Pos. 1
Control panel.
Pos. 2
Fast coupling positive polarity.
Pos. 3
Fast coupling negative polarity.
Pos. 4
Mains switch. In the “O” position the welder is off.
Pos. 5
Connector for connecting the interconnection cable
or auxiliary welding controls.
Pos. 6
Fast coupling reverse polarity.
Pos. 7
Connector for connecting the cooling system.
Pos. 8
Mains cable.
Table 2
Model
DIX PI 3006.M PULS
DIX PI 4006.M PULS
DIX PI 4606.M PULS
MIG-MAG welding
Input power @ I
2
Max
V
18,8
25,5
32
Delayed fuse (I
2
@ 60%)
A
25
30
40
Duty cycle @ 50% (40°C)
A
330
(40% ED)
400
500
Mains cable
Length
Section
m
mm²
4,0
4 × 2,5
4,5
4 × 4
4,5
4 × 6
Ground cable section
mm²
50
50
70