43
5 - HOLD
JOB/SEQUENCES
When welding ends the fields in the display must show the same values that were displayed during welding, with the difference
that they are now values defined as
HOLD
. In this phase the
DISPLAY
shows the
HOLD
box highlighted, while on the WF 793.M
panel the
HOLD F
UNCTION
LED
flashes until the end of the
HOLD Function
. If the
HOLD Function
is Interrupted via a panel, it will also
be interrupted automatically on the other (WF 793.M) and vice-versa.
WARNING:
All the parameters saved within a JOB (including SPECIAL FUNCTIONS (Fx)) can be viewed but not edited!
„PI 3006.M PULS“ / „PI 4006.M PULS“ / „PI 4606.M PULS“ CONTROL PANEL
m/min
V
11.1 33.3
013
HOlD
mm
2.8
0
001
001
Fe G3 SI-1 Ø 0.8 Ar 16-20% CO2
1011 - Welding sequence
HOlD
„WF 793.M“ CONTROL PANEL
HOLD Function LED
Summary of Contents for DIX PI 3006.M PULS
Page 10: ...10 2101EA86 Wiring diagram ...