55
Software
Descrizione
I/O STATUS
FAN OFF
WATER COOLER PUMP
OFF
E0.3 UNDER VOLTAGE
OFF
E0.2 OVER VOLTAGE
OFF
E0.4 OVER CURRENT
OFF
T°C THERMAL PROTECTION
OFF
VRD OFF
WATER COOLER PRESENCE
ON
COOLING PLANT PRESSURE
OFF
I/O STATUS
The status of the inputs and outputs on the generator.
REMOTE CONTROLS STATUS
ANALOGIC INPUT 1
0
ANALOGIC INPUT 2
0
ANALOGIC INPUT 3
0
ANALOGIC INPUT 4
0
TORCH TRIGGER INPUT
OFF
UP TRIGGER INPUT
OFF
DOWN TRIGGER INPUT
OFF
AUX-IN OFF
REMOTE CONTROL
The status of the inputs:
•
ANALOGUE INPUT 1 (synergic remote control input)
•
ANALOGUE INPUT 2 (arc length remote control input)
•
ANALOGUE INPUTS 3 & 4 not connected
•
TORCH BUTTON
•
UP AND DOWN BUTTONS on the torch
•
AUX-IN not connected
ENABLED OPTIONS
COLD VISION.COLD
ECP
EXTENDED CURVES PACKAGES
PIPE VISION.PIPE
POWER VISION.POWER
PULSED PULSED
ULTSPEED VISION.ULTRASPEED
ENABLED OPTIONS
The special programs enabled, specifically:
•
PULSED
•
ECP estended curves package
•
DIX ARC COOL
•
DIX ARC COOL PIPE
•
DIX ARC HEAVY
•
DIX ARC MEGA FAST
(continua)
The contents of thus menu are for information only, the operator cannot change anything they can only read the information con-
tained by scrolling the various options available in the menu by rotating the
ENCODER K
NOb
- SX
.
To exit the
INFO Menu
and go back to the
SETUP Menu
:
•
Push the
MENU K
Ey
.
NETWORK
SETUP Menu
This menu is used to view the settings for the Ethernet network if connected. If not, the following image is displayed:
LINK STATUS
NOT ACTIVE
CONFIGURATION DHCP
IP ADDRESS
NETMASK
GATEWAY
Digitech Vision 5000 [FX00204904080100]
Function
Description
LINK STATUS
LINK STATUS
NOT ACTIVE
CONFIGURATION DHCP
IP ADDRESS 169.254.136.178
NETMASK 255.255.0.0
GATEWAY 0.0.0.0
Digitech Vision 5000 [FX00204904080100]
This indicates that the welding machine has an active connection to the Ethernet
network.
CONFIGURATION
LINK STATUS
NOT ACTIVE
CONFIGURATION DHCP
IP ADDRESS 169.254.136.178
NETMASK 255.255.0.0
GATEWAY 0.0.0.0
Digitech Vision 5000 [FX00204904080100]
This indicates the type of network configuration used.
The DHCP protocol is obligatory.
(continued)
Summary of Contents for DIX PI 3006.M PULS