MTG200 Trunk Gateway User Manual
21
Figure 2-6-5 SS7 MTP Link Add
SS7 MTP link description
Trunk No
It is consistent with foregoing “Trunk No” of SS7 trunk.
Link No
Equipment maximum support 2 signaling links, these two links share workload, when one
link fails, the other link will take over the load until restore from failure, and then they will
share the load again.
Signaling Link Code
If a signaling point has established several signaling links, then the code of each signaling
link will begin from 0.
E1/T1 Port No
Indicate which E1/T1 this link is established on, it is stipulated that such numbering is
carried out according to the physical position of E1/T1.
Channel No
Indicate time slot that link is established on. It is assigned to 1 or 16 for time slot, the default
is 16 time slot.
2.6.3 SS7 Circuit
Figure 2-6-5 SS7 Circuit