MTG200 Trunk Gateway User Manual
6
Table 1-2-1 MTG200 Rear View Description
Interface
Description
PWR
The power interface. DC12V.1A
Port0-Port3
E1/T1 Port. There are 4E1 options.
FE0
The Service Ethernet Interface, standard 10/100BASE-TX Ethernet interfaces. Default IP
address is 192.168.1.111
,
default subnet mask is 255.255.255.0
FE1
Management Ethernet Interface. Default IP address is 192.168.11.1, default subnet mask is
255.255.255.0
1.2.2 Front View
Figure 1-2-2 MTG200 Front View
Table 1-2 -2 MTG200 Front View Description
LED
Function
Color
Work Status
POWER
Power status indicator
Green
Off
:
Power is off
On: Power is on
RUN
Register indicator
Green
Slow blinking: Unregister
Fast blinking: Register
ALM
The failure of device
indicator
Yellow
Off: Normal
On: Failed
RST
Reset button, it is used to restart the device
CONSOLE
RS232 console port: it can be used to debug and configure the device. The baud rate is 115200
bps.
E1/T1
Indicating the connection
state of device E1/T1.
Green
Off
:
E1/T1 port connection normal
On: E1/T1 port connection and sending/ receiving
message normal
Flash:E1/T1 port connection failed
LINK
Green
Off: Network connection failed