MTG200 User Manual
15
Dinstar Technologies Co., Ltd.
Table 2-4-2 Description of Add PRI Trunk
Trunk No
The number of PRI trunk; when user add PRI trunk, 0~7 number will appear in the
pull-down menu to be selected (the number here depends on E1/T1 physical port
number actually existed in equipment). After trunk number is established, filling in
corresponding port number in “E1/T1 Port No.”, so as to assign E1/T1 to designated
trunk; Each PRI trunk corresponds to a E1/T1 port.
Trunk Name
Description of PRI trunk
Channel ID
Channel ID of E1/T1 ports, this number definition generally starts from 0.
D-channel
Indicate whether E1/T1 supports D channel, the default is Yes.
E1/T1 Port No
E1/T1 port number is numbered according to the physical position of E1/T1, it generally
starts from 0.
Protocol
Interface type of PRI. There are two types are available: ISDN and QSIG; the default is
ISDN.
Switch Side
Indicate PRI network property of E1/T1, it is divided into: “User side” and“Network
side”. When PRI loopback is carried out, the network properties of E1/T1 port at both
receiving and sending sides must be different.
Alerting Indication
The ring signal include Alerting and Progress
2.5 PSTN Group Config
2.5.1 E1/T1 Parameter
Figure 2-5-1 E1/T1 Parameter