5 Configurations on Web Interface
UC200-2S2O User Manual
Copyright©2011-2018 Dinstar
49
Message Format
The
message formats to display caller information, including
Display Name and CID, Only display Name, Only display CID
Send CID Before
Ring
If it is enabled, the CID will be shown before ringing; otherwise,
CID will be displayed after ringing
Send CID After
Ring(ms)
If it is enabled, the CID will be shown after ringing; otherwise, CID
will be displayed before ringing
Delay Timeout After
Ring (ms)
The maximum interval between ringing and displaying of CID
Impedance
The impedance
(
SLIC
)
matched with analog phones
REN(Ringer
Equivalency
Number)
REN is used to determine how many devices can be connected by
FXS/FXO telephone lines. The range of REN is from 1 to 4
Polarity Reverse
If polarity reverse is on, call tolls will be calculated based on the
changes in voltage. If polarity reverse is off, you need to set the
time for offhook detect and call tolls will be calculated starting
from the set time
Send Flash Hook via
SIP INFO
If this parameter is on, signal of flash-hook is sent via SIP INFO
Offhook Current Detect
Threshold
The current threshold used to detect the offhook status of FXS/FXO
Onhook Current Detect
Threshold
The current threshold used to detect the onhook status of FXS/FXO
Dialplan
The rules for dialing. The UC200-2S2O device supports regular
expression. Please make reference to
Profile
Dialplan
section.