background image

3 OF 8

IG121620-3.0

AlphaTECH

®

 LED Strip Light

 INSTALLATION GUIDE

AlphaTECH

® 

LED STRIP LIGHT

INSTALLATION GUIDE

INDOOR/OUTDOOR INSTALLATION

Connect AlphaTECH

®

 LED Strip Light, then press 

firmly  into  channel.  If  necessary,  include  a  small 

amount of silicone adhesive/sealant within the 

channel to hold it in place.

*Note: Placing AlphaTECH

®

 LED Strip Light within another 

channel may not be necessary nor recommended.

1

2

UNDERWIRE CHANNEL

Bottom Entry

H .41 in.

(10.4mm)

W .62 in.

(15.74mm)

+

+

H .62 in.

(15.74mm)

W .76 in.

(19.3mm)

W .76 in.

(19.3mm)

L 6 in.

(152.4 mm)

 2.5 in. (63.5mm) 20/2 AWG Wire

 2.5 in. (63.5mm) 20/2 AWG Wire

 2.5 in. (63.5mm) 20/2 AWG Wire

 2.5 in. (63.5mm) 20/2 AWG Wire

L 48 in.

(1219.2 mm)

End Entry

or

Bottom Entry

Bottom Entry

a

Fasten mounting clip to surface. If running wire 

under  channel,  place  AlphaTech  wires  in  offset 

(smaller) side of strain relief, and any thru-wires on 

opposite (wider) side of strain relief. 

Place Underwire Channels end-to-end onto 

mounting clip, over strain relief, to create smooth, 

linear surface.

3

Beginning of run

(6” Connection Channel)

Continue run

(48” Channels)

Run Completion

(48” Channel)

Additional connections

(6” Connection Channel)

Connector/AlphaTech wire

(place in offset)

Thru-wires

(place opposite of offset)

Mounting Clip

Strain relief

Summary of Contents for AlphaTECH LED STRIP LIGHT

Page 1: ... the warranty will be void 4 Do not use if there is any damage to the fixture or wiring Inspect periodically 5 Do not install in direct sunlight or damage to the LED phosphor will occur 6 Do not attempt to fix this product in the field 7 Failure to follow safety warnings and installation instructions will void the warranty for this product SAFETY WARNINGS HANDLE PRODUCT WITH CARE DO NOT BEND LED S...

Page 2: ...ble wire is installed between driver fixture and any controls in between When choosing wire factor in voltage drop amperage rating and type in wall rated wet location rated etc TEST CONNECTION Prior to mounting attach to Class 2 LED Driver turn on power and test connection to ensure system is operating properly Turn off power again before mounting MOUNT AlphaTECH LED STRIP LIGHT Indoor Outdoor Ins...

Page 3: ...m L 6 in 152 4 mm 2 5 in 63 5mm 20 2 AWG Wire 2 5 in 63 5mm 20 2 AWG Wire 2 5 in 63 5mm 20 2 AWG Wire 2 5 in 63 5mm 20 2 AWG Wire L 48 in 1219 2 mm End Entry or Bottom Entry Bottom Entry a Fasten mounting clip to surface If running wire under channel place AlphaTech wires in offset smaller side of strain relief and any thru wires on opposite wider side of strain relief Place Underwire Channels end...

Page 4: ...NTING CLIP 1 2 NSF 3 93mm dia INDOOR OUTDOOR INSTALLATION Press AlphaTECH LED Strip Light firmly into channel If necessary include a small amount of silicone adhesive sealant within the channel to hold it in place Press channel around the outside edges of AlphaTECH Strip Light Note Placing AlphaTECH LED Strip Light within another channel may not be necessary nor recommended 1 2 CHANNEL b c ...

Page 5: ...ranty is not voided Always consult with your pool supplier and contractor for proper installation of 3rd party products Wall Mount Coping Mount Recessed Mount Concrete Pools Only Channel only Channel only Concrete Pools Fiberglass Pools Vinyl Line Pools Concrete Pools Only Channel or Clips Mount channel to dry surface using either a mounting clip or chlorine resistant waterproof adhesive Allow adh...

Page 6: ...ing Ensure a compatible driver and or dimming control is installed Check for loose connections Lights are turning on off repeatedly Ensure driver is not overloaded An overloaded driver will trip the internal auto reset of driver repeatedly turning the system on off 5 TURN POWER ON AT CIRCUIT BREAKER 6 ATTACH DRIVER AND LIGHTING CONTROL Verify a compatible driver is installed Utilize applicable wir...

Page 7: ...ropriate wire gauge type V V LED Tape Light Fixture 8 REIGN 12 24V Dimmer4 V V L N AC Power 50 60Hz INPUT OUTPUT 1 Driver may not require a fault ground connection Refer to driver specifications for additional information 2 Install a compatible Class 2 constant voltage driver Refer to each driver specification sheet for full power ratings load deratings 3 InstallaClass2constantvoltagedrivercompati...

Page 8: ...A 60 W 2 5 A 70 W 2 9 A 80 W 3 3 A 100 W 4 2 A 22 AWG 53 ft 27 ft 17 ft 13 ft 11 ft 9 ft 8 ft 7 ft 6 ft 18 AWG 134 ft 68 ft 45 ft 33 ft 27 ft 22 ft 19 ft 17 ft 14 ft 16 AWG 215 ft 109 ft 72 ft 54 ft 43 ft 36 ft 31 ft 27 ft 22 ft 14 AWG 345 ft 174 ft 115 ft 86 ft 69 ft 57 ft 49 ft 43 ft 36 ft 12 AWG 539 ft 272 ft 181 ft 135 ft 108 ft 90 ft 77 ft 68 ft 56 ft 10 AWG 784 ft 397 ft 263 ft 197 ft 158 ft...