background image

BURE XL

DIRECTHEALTHCAREGROUP.COM

2

Contents

1. 

Intended 

Use            03

2. 

Contraindications, 

Precautions 

and 

Warnings 

       03

3. 

Raising 

and 

Lowering 

the 

Frame 

         04

4. 

Adjusting 

the 

Handles 

          04

5. 

Left 

and 

Right 

Adjustment 

of 

Armrests 

        04

6. 

Locking/Unlocking 

Castors 

          04

7. 

Control 

Box 

Wiring 

           05

8. 

Battery 

Charging 

           05

9. 

LED 

on 

Control 

Box 

and 

Battery 

         05

10. 

Maintenance 

           06

11. 

General 

Maintenance 

Advice 

Cleaning 

        07

12. 

Technical 

Specifications 

          07

13. 

Safety 

Instructions 

           08

14. 

Recycling/Disposal           08

15. 

Warranty 

            08

16. 

Electrical 

System 

Technical 

Data 

(T-motion/Linak)       09

17. 

Parts 

List 

            10

18. Spare Parts            11 
19. 

Accessories            11

20. 

Table 

of 

Symbols 

           12

 

Bure XL

Bure XL was designed for the bigger, heavier patient and therefore provides extra space and strength. 
Because extra powerful aids are required in the care and nursing of heavier patients, Bure XL is always 
supplied with electric drives.

Summary of Contents for 56-315

Page 1: ...nual DIRECTHEALTH C ARE GR OUP COM Manual no 801 rev 1 210604 SWL 240 kg 529 lbs 56 315 56 315 75 56 315 75 UK 56 315 75 PU 56 315 PU AUS 56 315 AUS 56 315 CAN 56 315 PU 56 315 PU UK 56 315 B 0 56 315 B 1 56 315 B 0 PU 56 315 S 56 315 UK 56 315 100 ...

Page 2: ...5 10 Maintenance 06 11 General Maintenance Advice Cleaning 07 12 Technical Specifications 07 13 Safety Instructions 08 14 Recycling Disposal 08 15 Warranty 08 16 Electrical System Technical Data T motion Linak 09 17 Parts List 10 18 Spare Parts 11 19 Accessories 11 20 Table of Symbols 12 Bure XL Bure XL was designed for the bigger heavier patient and therefore provides extra space and strength Bec...

Page 3: ... is not in use Check the function of the brakes before use Inspect the device regularly to detect any signs of damage If there are any visible signs of damage contact Direct Healthcare Group Customer Service In case of an electrical model of the device check that the hand control does not show signs of wear before every use Check that the hand control markings are in accordance with the lifting fu...

Page 4: ...e Group representative When lifting the device only use the denoted handholds At least two people are required for lifting the device Do not leave a user or patient unattended when the device is being used Never move the lift by pulling on the actuator or gas piston The device must not be lowered into water The device must not be left or stored in a damp or humid environment The device must not be...

Page 5: ...ast 24 hours before first time use 9 LED on Control Box and Battery Control box green light when power is available from battery mains socket Battery The LED flashes green during charging ON OFF To use the product press ON The green lamp will begin to flash Use the OFF button hold down for 5 s to switch off the battery if the product will not be used for an extended period The LED will shows a con...

Page 6: ...rom play Height adjustment via remote control is functional The electric actuator must run smoothly at a constant speed Fit new guide sleeves in frame or end plugs in chrome tubes as required Tighten all lock bolts Replace clamps Tighten the attachment fitting concerned replace bolts lock nuts as necessary Check that the battery remote control actuator are connected in accordance with the wiring d...

Page 7: ...ifetime Replace damaged parts immediately must be done by experienced personnel If the product is to be cleaned in a washing tunnel washing cabin use PU cushions The product is only intended for indoor use 12 Technical Specifications Dimensions apply to Walkers with 125 mm castors Part No Product Product width Max user weight Length Height Armrest Internal dimension 56 315 Bure XL EL 90cm 240kg 84...

Page 8: ...ncluding batteries must be removed and recycled as electrical components Ask your local recycling station for further information about how the different materials in the product metals plastics electronics should be recycled 15 Warranty We provide two years warranty against manufacturing faults does not apply to wear parts For further information or enquiries please contact Direct Healthcare Grou...

Page 9: ...00N 1200 N Self locking push 1000N 1000N 7A 3 A Current 6 6 1 0 A 2 6 0 4 A 7A ut 7 A in 3A ut 3 A in Colour Black Aluminium White White Stroke 400mm 55mm 400 mm 55 mm Mounting dim 605mm 167mm 606 2 mm 165 2 mm Encapsulation IP66 IP66 IPX6 IPX6 IEC60601 1 3rd revision Control box Battery Producer T Motion Linak Voltage 24V 230V 24V Capacity 2 0AH 2 25 Ah Encapsulation IP66 IPX6 Colour Black White ...

Page 10: ...t Washer 2 D E F Handle and grip Clamp Knob 7 Protective plate left right 3 Upper frame 8 S T U V Remote control Holder remote control Battery Control box 4 G H I J Chromium plated tube Attachment bolt Washer End bushing 9 X Y Actuator raise lower Bolt washer 2 pcs nut attachment at bottom and top 5 K L Frame with battery shelf Guide sleeve ...

Page 11: ...6 357 Wheel without brake 100 mm 56 358 Wheel with brake 100 mm N 56 360 Wheel without brake 125 mm 56 361 Wheel with brake 125 mm 56 387 Wheel with brake 75 mm E 56 356 Locking clamp handle F 56 363 Knob for adjusting handle B 56 364 Knob for adj width of armrest plates S 56 370 1 Hand control 2channel raise lower LA31 S 56 370 Hand control 2channel raise lower LA28 56 374 1 Power cable LA31 56 3...

Page 12: ...Medical Device Read the manual Caution Product Code Manufacturer information Batch Code Type BF according to the degree of protection against electric shock The device is intended for indoor use WEEE Symbol May not be discarded in domestic waste Class II Equipment Duty Cycle 2 min in active ON mode 18 min in rest OFF mode 20 Table of Symbols ...

Page 13: ...atan 35 SE 164 40 Kista Sweden Tel 46 0 8 557 62 200 info directhealthcaregroup com www directhealthcaregroup com Medical Device Class I The product complies with the re quirements of the Medical Devices Regulation 2017 745 Medical Device Class I ...