1. Intended Use

Walkers are indoor, movable and portable assistive aids, which together with approved accessories are 
intended to be used for transfer from sitting to standing positions, and walking training. Walkers are to be used 
by persons with reduced muscular strength, who shall be able to stand and perform simple leg movements. 
Walkers are to be used for leaning on when walking and standing during early mobilization training. Walkers 
and accessories are intended for indoor use only in Home Healthcare environment and Professional Healthcare 
facility environment.

2. Contraindications, Precautions and Warnings

Contraindications

•  The device may not be used by patients above the maximum weight indicated on the label of the device.

Precautions

•  Check that the device is used on a dry and flat surface.

•  Check the device is correctly mounted/assembled before its first use.

•  Check the device after every folding/disassembly after any transport.

•  Check height adjustment and leg spreading motions and inspect the actuators’ or gas pistons’ full ranges.

•  Activate the brakes whenever the device is not in use.

•  Check the function of the brakes before use.

•  Inspect the device regularly to detect any signs of damage. If there are any visible signs of damage, 

contact Direct Healthcare Group Customer Service. 

•  In case of an electrical model of the device, check that the hand control does not show signs of wear 

before every use.

•  Check that the hand control markings are in accordance with the lifting functions.

•  Check the battery status of an electrically operated model, before using the device.

•  It is important to never leave the user alone during the transfer.

•  Warranty applies only if repairs or alterations are made by personnel who are authorized by Direct 

Healthcare Group.

•  Ensure that there are no obstacles or people in the way of the device, when moving.

•  Handle batteries with care. Do not drop.

•  Use only batteries and cables that are intended for the device as instructed by the manufacturer.

•  Verify that potential accessories that might be used are properly attached to the device before use.

•  Low speed is recommended when moving with the device.

•  Take care not to drive the device over thresholds with high speed or force. Approach the threshold with 

lower speed and communicate the coming threshold to the user.

•  Keep the instructions for use together with the product so that it can be used as a reference if necessary.

Summary of Contents for 56-315

Page 1: ...nual DIRECTHEALTH C ARE GR OUP COM Manual no 801 rev 1 210604 SWL 240 kg 529 lbs 56 315 56 315 75 56 315 75 UK 56 315 75 PU 56 315 PU AUS 56 315 AUS 56 315 CAN 56 315 PU 56 315 PU UK 56 315 B 0 56 315 B 1 56 315 B 0 PU 56 315 S 56 315 UK 56 315 100 ...

Page 2: ...5 10 Maintenance 06 11 General Maintenance Advice Cleaning 07 12 Technical Specifications 07 13 Safety Instructions 08 14 Recycling Disposal 08 15 Warranty 08 16 Electrical System Technical Data T motion Linak 09 17 Parts List 10 18 Spare Parts 11 19 Accessories 11 20 Table of Symbols 12 Bure XL Bure XL was designed for the bigger heavier patient and therefore provides extra space and strength Bec...

Page 3: ... is not in use Check the function of the brakes before use Inspect the device regularly to detect any signs of damage If there are any visible signs of damage contact Direct Healthcare Group Customer Service In case of an electrical model of the device check that the hand control does not show signs of wear before every use Check that the hand control markings are in accordance with the lifting fu...

Page 4: ...e Group representative When lifting the device only use the denoted handholds At least two people are required for lifting the device Do not leave a user or patient unattended when the device is being used Never move the lift by pulling on the actuator or gas piston The device must not be lowered into water The device must not be left or stored in a damp or humid environment The device must not be...

Page 5: ...ast 24 hours before first time use 9 LED on Control Box and Battery Control box green light when power is available from battery mains socket Battery The LED flashes green during charging ON OFF To use the product press ON The green lamp will begin to flash Use the OFF button hold down for 5 s to switch off the battery if the product will not be used for an extended period The LED will shows a con...

Page 6: ...rom play Height adjustment via remote control is functional The electric actuator must run smoothly at a constant speed Fit new guide sleeves in frame or end plugs in chrome tubes as required Tighten all lock bolts Replace clamps Tighten the attachment fitting concerned replace bolts lock nuts as necessary Check that the battery remote control actuator are connected in accordance with the wiring d...

Page 7: ...ifetime Replace damaged parts immediately must be done by experienced personnel If the product is to be cleaned in a washing tunnel washing cabin use PU cushions The product is only intended for indoor use 12 Technical Specifications Dimensions apply to Walkers with 125 mm castors Part No Product Product width Max user weight Length Height Armrest Internal dimension 56 315 Bure XL EL 90cm 240kg 84...

Page 8: ...ncluding batteries must be removed and recycled as electrical components Ask your local recycling station for further information about how the different materials in the product metals plastics electronics should be recycled 15 Warranty We provide two years warranty against manufacturing faults does not apply to wear parts For further information or enquiries please contact Direct Healthcare Grou...

Page 9: ...00N 1200 N Self locking push 1000N 1000N 7A 3 A Current 6 6 1 0 A 2 6 0 4 A 7A ut 7 A in 3A ut 3 A in Colour Black Aluminium White White Stroke 400mm 55mm 400 mm 55 mm Mounting dim 605mm 167mm 606 2 mm 165 2 mm Encapsulation IP66 IP66 IPX6 IPX6 IEC60601 1 3rd revision Control box Battery Producer T Motion Linak Voltage 24V 230V 24V Capacity 2 0AH 2 25 Ah Encapsulation IP66 IPX6 Colour Black White ...

Page 10: ...t Washer 2 D E F Handle and grip Clamp Knob 7 Protective plate left right 3 Upper frame 8 S T U V Remote control Holder remote control Battery Control box 4 G H I J Chromium plated tube Attachment bolt Washer End bushing 9 X Y Actuator raise lower Bolt washer 2 pcs nut attachment at bottom and top 5 K L Frame with battery shelf Guide sleeve ...

Page 11: ...6 357 Wheel without brake 100 mm 56 358 Wheel with brake 100 mm N 56 360 Wheel without brake 125 mm 56 361 Wheel with brake 125 mm 56 387 Wheel with brake 75 mm E 56 356 Locking clamp handle F 56 363 Knob for adjusting handle B 56 364 Knob for adj width of armrest plates S 56 370 1 Hand control 2channel raise lower LA31 S 56 370 Hand control 2channel raise lower LA28 56 374 1 Power cable LA31 56 3...

Page 12: ...Medical Device Read the manual Caution Product Code Manufacturer information Batch Code Type BF according to the degree of protection against electric shock The device is intended for indoor use WEEE Symbol May not be discarded in domestic waste Class II Equipment Duty Cycle 2 min in active ON mode 18 min in rest OFF mode 20 Table of Symbols ...

Page 13: ...atan 35 SE 164 40 Kista Sweden Tel 46 0 8 557 62 200 info directhealthcaregroup com www directhealthcaregroup com Medical Device Class I The product complies with the re quirements of the Medical Devices Regulation 2017 745 Medical Device Class I ...

Reviews: