7 |
P a g e
Smart-Pad Operation Manual
INSTALLATION NOTICE
BEARING: Use the rack or mount that is designated by the manufacturer. If the mounting bracket is
not from the manufacturer, the bearing capacity should not be less than 4 times its actual bearing
weight. The bearing capacity of the supporting disk for bearing the rack should not be less than 4
times its actual bearing weight, and make sure the interactive monitor is stable.
The mounting surface bearing the interactive monitor should be firm with enough bearing capacity
and should not be less than 4 times its actual bearing weight. When the mounting surface is the wall
or rooftop of buildings, it must be solid brick, concrete or other strength equivalent mounting
surface. If the mounting surface is made of loose materials (old building brick wall, woodiness, solid
brick wall, metal or non-metal structures, or the decoration layer of the mounting surface is too
thick, the strength of surface is obviously deficient and corresponding reinforcement and support
measures should be taken to avoid safety hazard.
HEAT DISSIPATION
COOLING
VENTILATION
Requirements
Distance to mounting surface(cm)
Nominal output
Left/right
Top
Bottom
Back
Above 100W
10
20
20
10
Notes:
When the monitor inlay wall or box, the vent area of bottom/flank/top sides should be no
less than 50% of packing surface and air circulation need to be kept well.
Diagram: * Refer to CAS 132-2006 Standard
INSTALLATION INSTRUCTION