background image

6

© 2011 Directed Electronics. All rights reserved.

Onboard Dual Stage Zone 2 Impact Sensor

There is a dual-stage impact sensor inside the control unit. Adjustments are 

made via the rotary control as indicated above. Since the impact sensor does 

not work well when mounted firmly to metal, we recommend against screwing 

down the control module. We recommend mounting the control module to a 

large wiring loom.

Important: 

When adjusting the sensor, it must be mounted in the same loca-

tion where it will be after the installation is completed. Adjusting the sensor 

and then relocating the module requires readjustment.

Bypassing Sensor Inputs

Sensors can be bypassed during auxiliary channel and add-on accessory op-

erations. During an auxiliary channel output apply ground to the H1/6 wire, 

the sensors will be bypassed and will not trigger the alarm until several seconds 

after the ground ceases. This is ideal for add-on remote starters and window 

control modules:

ADD-ON REMOTE

START UNIT

Impact sensor adjuster

Summary of Contents for 3100

Page 1: ...d for installation by a professional installer only Attempts to install this product by a person other than a trained professional may result in severe damage to a vehicle s electrical system and components 2011 Directed Electronics Vista CA N3100 2011 12 ...

Page 2: ...rrupt Harness H3 4 Plug in LED and Valet Program switch 4 Internal Programming Jumper 5 Light Flash 5 Onboard Dual Stage Zone 2 Impact Sensor 6 Bypassing Sensor Inputs 6 Nuisance Prevention Circuitry NPC 7 Table of Zones 7 Remote Control Programming 8 Function Table 9 System Feature Programming 9 Feature Table 10 Feature Descriptions 11 Troubleshooting 13 ...

Page 3: ...control module Two 4 button or 3 button remote controls The plug in LED system status indicator The plug in Valet button An on board dual zone impact sensor A high powered siren The 12 pin primary harness The 3 pin door lock harness The plug in starter interrupt harness ...

Page 4: ...uster Main Harness 12 pin Connector H1 H1 1 ORANGE 500 mA Ground When Armed Output H1 2 WHITE Selectable Light Flash Output H1 3 WHITE BLUE 200 mA Channel 3 Validity Output H1 4 BLACK WHITE 200 mA Interior Light Illumination Output H1 5 GREEN Door Trigger Input Zone 3 H1 6 BLUE Multiplex Trigger Input Zone 1 H1 7 VIOLET Door Trigger Input Zone 3 H1 8 BLACK Chassis Ground Input H1 9 YELLOW Ignition...

Page 5: ...ther a 451M Door Lock Relay Satellite or two relays will be required Important For additional Door Lock information refer to Tech tip 1041 at www directechs com or contact your local distributor Horn Honk 3 pin connector H 1 OPEN NO FUNCTION H 2 BROWN BLACK 200 mA HORN HONK OUTPUT H 3 OPEN NO FUNCTION This wire outputs a single pulse when arming the system and two puls es when disarming the system...

Page 6: ...rter interrupt output wire Important These two black wires are interchangeable Control Module Plug in LED and Valet Program switch These plug into the control module The status LED plugs into the white 2 pin socket while the valet program switch plugs into the blue 2 pin connector The status LED and valet switch each fit into a 9 32 inch hole Control Module Blue 2 pin port Valet Program button Whi...

Page 7: ...d the unit will output 12V on the H1 2 WHITE wire In the position the on board relay is disabled The H1 2 WHITE wire will supply a 200 mA output suitable for driving factory parking light relays To access the jumper open the control module Important For parking light circuits that draw 10 amps or more the internal jumper must be switched to a light flash output P N 8617 or a standard au tomotive S...

Page 8: ...om Important When adjusting the sensor it must be mounted in the same loca tion where it will be after the installation is completed Adjusting the sensor and then relocating the module requires readjustment Bypassing Sensor Inputs Sensors can be bypassed during auxiliary channel and add on accessory op erations During an auxiliary channel output apply ground to the H1 6 wire the sensors will be by...

Page 9: ...the system is triggered by an open door for three full 30 second cycles one and one half minutes the system bypasses the doors until the trigger ceases Disarming and rearming does not reset NPC To reset NPC 60 minutes must pass without a trigger or it is reset when the ignition is turned on The system is able to trigger repeatedly disarm re arm and allow NPC to bypass a faulty zone When disarming ...

Page 10: ...button to select the function After pressing and releasing corresponding to the function then press the Valet button once more and hold it The LED flashes and the siren sounds to confirm the selection 4 While holding the Valet button press the remote button that controls the selected function The siren emits one long sound to confirm program ming 5 Release the Valet button to finish and exit progr...

Page 11: ... to default settings and may need to be changed to accommodate vehicle specific requirements and user prefer ences To change the system feature settings use the following procedure Important Test the systems Ignition input Door trigger input Valet button Status LED and siren for proper operation before proceeding 1 Select a System Feature and required number of Valet button presses as described in...

Page 12: ...g is exited when one of the following occurs Turn ignition ON Close the doors Press Valet button too many times 15 seconds or more lapses between steps Feature Table Valet but ton presses Chirps Flashes LED ON OPTION 1 chirp LED OFF OPTION 2 chirps 1 Active Arming Passive Arming 2 Confirmation Chirps ON Confirmation Chirps OFF 3 Ign controlled Locking ON Ign controlled Locking OFF 4 Active Locking...

Page 13: ... OFF arm and disarm chirps are defeated warn away chirps are active 3 Ign controlled Locking ON the door lock unlock outputs activate when ignition is turned on off OFF the door lock unlock outputs do not activate when ignition is turned on off Note Doors must be closed for ignition lock to work 4 Active Passive Locking Active Locking The doors do not lock when passively arming only when using the...

Page 14: ...n active door trigger when arming does not generate an alert output 9 Double Pulse Lock OFF Lock output provides a single pulse ON Lock output provides a double pulse 10 Comfort Closure OFF Comfort Closure is defeated when arming On 800mS after door lock pulse or 2nd pulse for double setting Door lock output turns on again for 20 seconds Important If the unit is disarmed while the 20 second timer ...

Page 15: ...en or the H1 7 violet wire instead Door input does not respond with the progressive trigger but with immediate full alarm Does the LED indicate that the trigger was caused by the impact sensor See Table of Zones section of this guide The impact sensor if set to extreme sensitivity may be detecting the door unlatching before the door switch sends its signal Reducing the sensitivity can solve this p...

Page 16: ...f nearly 100 patents and Innovation Awards in the field of advanced electronic technology Quality Directed Electronics products are sold and serviced throughout North America and around the world Directed Electronics is committed to delivering world class quality products and ser vices that excite and delight our customers Directed Electronics Vista CA 92081 www directed com 2011 Directed Electron...