background image

5

© 2007 Directed Electronics - all rights reserved

Multi-level security arming

(If programmed 

ON

)

Multi-Level Security Arming allows the user to select sensors to be

active or bypassed when the system is armed. Multi-Level Security

Arming can only be accessed if the function is set ON (option 3-2)

By pressing the LOCK button more than once within 3 and 7 seconds

of arming the system activates Multi-Level Security Arming. If the LOCK

button is pressed again the unit cancels the bypass of the sensors.

There are different security levels which can be selected,  as follows:

Step

Lock Button
pressed

Number of Siren
Chirps

Armed State with
Zone Bypassed

1

Once

1 Chirp

No Zone Bypassed

2

Twice

3 Chirps, 3 flashes Zone 2 & 4

Bypassed

3

If the Lock button is pressed again anytime, the system will
return to step 1. The user can repeat the steps provided the
LOCK button is pressed between 3 and 7 seconds and no
other buttons are pressed.

Summary of Contents for 3902V

Page 1: ...Model 3901V 3902V 3903V Owner s Guide V e h i c l e S e c u r i t y S y s t e m ...

Page 2: ...ch proves to be defective in workmanship or material under reasonable use FOR A CHARGE OF 45 00 SO LONG AS THE AFOREMENTIONED CONDITIONS HAVE BEEN MET The unit must be returned to Directed postage pre paid along with a legible copy of the receipt including the information below and a cashier s check or money order made payable to Directed Electronics in the amount of 45 00 This warranty is non tra...

Page 3: ... of incidental or consequential damages This warranty gives you specific legal rights and you may also have other rights which vary from state to state This warranty is void if the unit has not been purchased from Directed or an authorized Directed dealer or if the unit has been damaged by accident unrea sonable use negligence Acts of God neglect improper service or other causes not arising out of...

Page 4: ...itter 6 Valet mode 7 Panic mode 7 Nuisance Prevention Circuitry 8 Diagnostics 10 Arming diagnostics 10 Disarming diagnostics 10 table of zones 11 Rapid resume logic 11 Glossary of terms 12 Notes 13 Contents Trademarks and copyrights Code Hopping Directed Doubleguard FailSafe Nuisance Prevention Circuitry NPC Silent Mode Soft Chirp Stealth Coding Stinger Valet and Warn Away are all Trademarks or Re...

Page 5: ...ty system Due to the complexity of this system it must be installed by an authorized dealer only Installation of this product by anyone other than an authorized dealer voids the warranty All dealers are provided with a preprinted dealer certificate to verify that they are authorized By carefully reading this Owner s Guide prior to using your system you will maximize the use of this system and its ...

Page 6: ...r a short siren sound and see the parking lights flash once While the sys tem is armed the status LED will flash about twice a second showing that the system is actively protecting your vehicle If you hear a second short siren sound after arming and see the status LED flashing in groups see Diagnostics section This extra short siren sound is called Bypass Notification This means a zone such as a d...

Page 7: ... Three seconds later the siren output changes to a continuous blast This progres sive response gives you time to disarm the system with your transmitter if you inadvertently open the door while the sys tem is armed while still providing instant response even if the door is immediately closed z Turning on the ignition key triggers the same progressive response as opening a door z If equipped the st...

Page 8: ...arming the system activates Multi Level Security Arming If the LOCK button is pressed again the unit cancels the bypass of the sensors There are different security levels which can be selected as follows Step Lock Button pressed Number of Siren Chirps Armed State with Zone Bypassed 1 Once 1 Chirp No Zone Bypassed 2 Twice 3 Chirps 3 flashes Zone 2 4 Bypassed 3 If the Lock button is pressed again an...

Page 9: ... damaged or disabled To do this you must have the ve hicle s ignition key and know where the integrated LED Valet switch is located The Valet switch is activated by pressing the LED status indicator Turn the ignition to the run position Press and release the integrated LED Valet switch within 10 seconds After a few seconds the LED will stop flashing and the vehicle should start If it does not you ...

Page 10: ...se the integrated LED Valet switch within 10 sec onds The status LED will light steady if you have entered Valet Mode To exit Valet Mode repeat the steps above The LED will turn off when exiting Valet Mode Panic mode If programmed On Step 3 2 If you are threatened in or near your vehicle you can attract attention by triggering the system with your transmitter If your factory keyless transmitter do...

Page 11: ...ree triggers are within 60 minutes of each other Your system will interpret this pattern of triggers as false alarms After the third trigger your system ignores or bypasses that sensor or switch along with any other sensors or switches sharing the same zone for 60 minutes If the bypassed sensor tries to trigger the system while it is being bypassed the 60 minute bypass period will start over This ...

Page 12: ...s not reset this function The only ways to reset a bypassed zone are for it to not trigger for 60 minutes or to turn on the ignition If test ing your system it is important to remember that this circuitry can cause zones to be bypassed and appear to stop work ing If five chirps are heard when disarming false alarm pro tection has engaged If you wish to clear the memory turn the ignition key on ...

Page 13: ...bypass notification The system will ignore the input that was active when it was armed until it goes away Three seconds later it will monitor that input normally Disarming diagnostics Extra disarm chirps are the tamper alert If four chirps are heard when disarming the system was triggered in your absence If five chirps are heard a zone was triggered so many times that false alarm prevention circui...

Page 14: ...Ignition input 6 Extra switch input if installed The LED will not report if the Warn Away response is triggered Rapid resume logic This system will store its current state to non volatile memory If power is lost and then reconnected the system will recall the stored state from memory This means if the unit is in Valet Mode and the battery is dis connected for any reason such as servicing the car w...

Page 15: ...al connection to the security system An input can be provided through a sensor pinswitch or by existing systems in the vehi cle such as ignition or courtesy lights Integrated LED Valet Switch A small push button switch with an integrated LED mounted somewhere in the vehicle The switch is used to override the alarm when a transmitter is lost or damaged or to put it into Valet Mode The LED indicates...

Page 16: ...13 2007 Directed Electronics all rights reserved Notes ...

Page 17: ...14 2007 Directed Electronics all rights reserved ...

Page 18: ...h twice Disarming without a transmitter Turn on the ignition Press the integrated LED Valet switch the pro grammed number of times within 10 seconds The system should now disarm If it does not you may have waited too long Turn the ignition off and on and try again To enter or exit Valet Mode Turn ignition to run position then turn to off position Press and release the integrated LED Valet switch w...

Page 19: ...16 2007 Directed Electronics all rights reserved ...

Page 20: ...17 2007 Directed Electronics all rights reserved ...

Page 21: ...rds in the field of advanced electronic technology DIRECTED is ISO 9001 registered Quality Directed Electronics products are sold and serviced throughout North America and around the world Call 8 80 00 0 2 27 74 4 0 02 20 00 0 for more information about our products and services Directed Electronics Inc Vista CA 92081 www directed com 2007 Directed Electronics Inc All rights reserved G3901V 2007 0...

Reviews: