35
© 2 0 0 8 d i r e c t e d e l e c t r o n i c s
feature by turning the ignition key to the RUN position and
pressing the Valet
®
button the programmed number of
times. AED is disabled when the system is in Valet
®
Mode.
➤
Full trigger response 3
30
0 or 60 seconds: This determines how
long the full triggered sequence lasts. Some states have laws
regulating how long a security system can sound before it is
considered a nuisance. If your installer is programming the
security system with the Directed Bitwriter, the full triggered
response can be programmed for any duration ranging from
1 to 180 seconds.
➤
Nuisance Prevention
®
Circuitry oon
n or off: Please refer to the
NPC
®
section of this manual for a complete explanation of
how NPC
®
operates. If NPC
®
is programmed off, the securi-
ty system will respond to inputs from any sensor indefinitely.
➤
Comfort Closure
O
Offff:: Windows will close upon locking the
vehicle.
➤
Forced Passive Arming Off
: If passive arming is on and a door
is left open the system will be armed after 30-seconds.
➤
Panic with Ignition Off
: Prevents the Panic button on the remotes
from activating panic with ignition On (not allowed in some
states).
note:
Because many states have laws regulating security
systems, programming NPC® off may cause your system
to violate state laws.
note:
This feature will only function if the Failsafe
®